background image

13
15

10

8

14

16

17

18

19

20

21

12

11

7

9

6

3

1

2

4

5

REAR PANEL

 

VOLTAGE  SELECTION PROCESS

 

CAUTION:Always disconnect AC power cord from unit, or AC power 

source before attempting to change fuse/voltage selector position!

 

WARNING!: Before AC power is applied to this device, 

always insure proper operating voltage selection is 

engaged to match AC power source being used.

 

voltage selection (2) may select 110-120V AC or 220-240V AC 

 

The fuse should be changed to the correct amperage rating.  For 

an input power voltage range of from 110VAC to 120VAC, use a 3.15 

amp rated, 250V 5 x 20 mm cartridge type time-delay fuse, which 

conforms to the international fuse classification "T3.15A

L

".  For 

an input power voltage range of from 220VAC to 240VAC, use a 

1.6

 amp rated, 250V 5 x 20 mm cartridge type time-delay fuse, 

which conforms to the international fuse classification "T

1.6

A

L

".

 

The IEC power cord that is correct for your locale can now be 

plugged into the IEC receptacle (3), and the Power switch (1) 

activated to turn on the powered PBK15

FM 

speaker system.

 

ON-OFF SWITCH (1)

 

This rocker switch supplies AC power to the PBK15

FM 

when 

switched to the ON position. The ON position is with the top side 

of the switch pushed 

"

in

 or nearly flush with the rear panel.

 

FUSE (2)

 

The unit is AC power line fuse protected from overloads 

and fault conditions with a slow-blow 5 x 20mm 250V fuse.

 

This fuse is located within the base of the IEC power cord 

connector (2), just below the IEC connector blades.   If the fuse 

fails, THE FUSE MUST BE REPLACED WITH THE SAME TYPE AND 

VALUE IN ORDER TO AVOID DAMAGE TO THE EQUIPMENT AND TO 

PREVENT VOIDING THE WARRANTY!

 

The fuse in the Peavey PBK15

FM 

can be replaced with a time-

delay type 5 x 20 mm size 250V rated fuse.

 

For 110-120VAC operation, a fuse rated at 3.15 amps 

and 250V should be used, which conforms to the 

international fuse classification  "T3.15A

L

".

 

For 220-240VAC 

operation

 a fuse rated at 

1.6

 amps and 250V should be used, which conforms to the 

international  fuse  classification  "T

1

.

6

A

L

".

 

If the unit continues to blow replacement fuses, do not keep replacing them, it should be taken to a qualified 

service center for repair.

 

To replace the fuse, be sure to remove the IEC power cord from the IEC socket.  The fuse holder tray is located 

beneath the IEC socket cavity.  Pry the fuse holder tray out with a small flat blade screwdriver placed under the 

center of the top edge of the fuse tray, and gently lever the fuse tray out.  The fuse is held in a clip in the fuse tray, 

and should be removed and replaced with a fresh 5 X 20mm 250V type fuse of the appropriate current rating.

 

Summary of Contents for 03617090

Page 1: ...PBK15FM Two way Powered Sound Reinforcement Enclosure Operating Manual www peavey com ...

Page 2: ......

Page 3: ...ease of portability A black powder coated perforated steel grille provides woofer protection and a professional appearance ThePBK15FMspeakersystempoweramplifierisalow distortionreliablepassiveair cooledunitproviding100W peakavailablepowerforthesystem Cooling is provided via a large heat sink for low noise and reliable operation under any conditions Line Input is via two RCA phono jacks to the prea...

Page 4: ...witch pushed in or nearly flush with the rear panel FUSE 2 The unit is AC power line fuse protected from overloads and fault conditions with a slow blow 5 x 20mm 250V fuse This fuse is located within the base of the IEC power cord connector 2 just below the IEC connector blades If the fuse fails THEFUSEMUSTBEREPLACEDWITHTHESAMETYPEAND VALUEINORDERTOAVOIDDAMAGETOTHEEQUIPMENTANDTO PREVENT VOIDING TH...

Page 5: ...USE 13 5 13 8V INITIAL CURRENT LESS THAN 2 1A WIRELESS MICROPHONES 6 Press ON OFF switch PWR indicator light The wireless receiver module is working PEAK 7 Indicator cavity peak signal Ignition to detect an input signal with a high or high output level that may cause a failure POWER LED 8 Illuminates green when the power switch is on and power is present MASTER VOLUME CONTROL 9 It is used to direc...

Page 6: ... the repeat functions In the FM Radio settings you can Auto search for stations delete stations or delete all the stations There are no settings available for the Bluetooth PLAY PAUSE A short press of the PLAY PAUSE button causes the operation to change from PLAY to PAUSE or from PAUSE back to PLAY STOP Press the STOP button to stop a file that is playing REPEAT Pressing the REPEAT button toggles ...

Page 7: ...arch mode 5 Select Bluetooth audio from search results on your phone or music device 6 Select OK or YES to pair your speaker system with your phone or music device When your PBK 15FM successfully pairs and connects with your phone or music device the LCD display will indicate the name of the device connected You will now be able to play music from your connected music source through your PBK 15FM ...

Page 8: ... track to play 0 9 Directly access tracks PICK SONG N A on this model ENTER Enters the settings menu MODE Toggles between the USB input FM radio and Bluetooth Remote Control WARNING Do not ingest the battery Chemical Burn Hazard The remote control supplied with This product contains a coin button cell battery If the coin button cell battery is swallowed it can cause severe internal burns in just 2...

Page 9: ...and driver EQ InputConnections Line Level two RCA phono jacks Mic Level One female XLR one 1 4 phone jack and two wireless microphones USB Input Port For connection of a USB thumb drive memory stick for playback of MP3 music files DO NOT PLUG A USB CABLE FROM A COMPUTER INTO THIS PORT The PBK15FM USB MP3 input and or the computer USB output can be damaged as a result Output Connections two RCA pho...

Page 10: ...orner 10kHz Nominal Amplifier Frequency Response before EQ 1 3 dB from 20 Hz to 20 kHz Hum and Noise Greater than 90 dB below rated power THD and IM Typically less than 1 Power requirements of Peavey PBK15FM System Nominal 50Watts 100 120VAC 50 60 Hz Fuse Type For 110 120 VAC USE International fuse classification T3 15AL cartridge style 5 x 20 mm size fuses with a 250V rating can be used For 220 2...

Page 11: ......

Page 12: ...i 白 cationssubjecttochangewithoutnotice Peavey Electronics Corporation 5022 Hartley Peavey Drive Meridian MS 39305 601 483 5365 FAX 601 486 1278 Logo referenced in Directive 2002 96 EC Annex IV OJ L 37 38 13 02 03 and defined in EN 50419 2005 The bar is the symbol for marking of new waste and is applied only to equipment manufactured after 13 August 2005 ...

Reviews: