PCAN-Diag 2 – BNC Connector
88
The trigger output is active if the measuring channel 2 (Ch2) of the
oscilloscope function is set to the CAN input:
Scope
>
Setting
>
Ch2 source
>
CAN-L
/
CAN-L CAN-Diff
/
CAN-Diff
When a trigger event occurs in the oscilloscope function, a trigger
signal is output on the BNC connector with the following properties:
Trigger output
Idle state
+3.3 V
Trigger event
0 V (falling edge)
Pulse duration
4 CAN bit timings, actual duration depending on the set
CAN bitrate
(at 500 kbit/s: 4 * 2
μ
s = 8
μ
s)
Delay to the internal
trigger
140 CAN bit timings, actual duration depending on the set
CAN bitrate; is displayed in the scope settings at
Scope
>
Setting
>
Trigger output delay
Course of the trigger signal, 20
μ
s/div