PCAN-Diag 2 – Setting Up the Device
14
Pin assignment for equipment with Single-wire CAN transceiver
(additional notes in the following subsections)
If the PCAN-Diag is equipped with a Low-speed or a Single-wire
CAN transceiver, a supply for the CAN transceiver must be set up
via
pin 9
of the D-Sub connector in addition to the common voltage
supply (section 2.2), otherwise the CAN communication does not
work.
Equipped with
transceiver type
Standard
Voltage range aux. supply
High-speed CAN
ISO 11898-2
no auxiliary supply
Low-speed CAN
ISO 11898-3
5 - 27 V DC
Single-wire CAN
SAE J2411
6 - 18 V DC
Attention!
Risk of electronics destruction by reverse polarity!
Make sure that the auxiliary supply is connected with the
correct polarity.
The D-Sub connector's shield is internally connected to voltage
ground (GND).
The connection of voltage ground (GND) to pins 3 and 6 can be
switched via
Device Settings
>
D-Sub GND connection
.