The system is designed for indoor use only but can also be housed in a suitable,
weatherproof enclosure, provided the environmental parameters meet operational
specifi cations detailed in this manual. The system should always be positioned in such a
way that it can be easily switched off and commissioning valves can be accessed easily.
Ensure a gap of at least 500mm is allowed around the skid system to
allow for air fl ow and accessibility.
System Positioning
Once in place, we recommend that the skid system is be bolted in place using the 8mm
thick L-brackets which have 16mm pre-drilled holes in them & we recommend using
M12 securing bolts. Always ensure that the system is installed by a Peak approved &
qualifi ed technician.
Rawl Bolt Installation
1. Drill a hole of required diameter and depth.
2. Remove debris and thoroughly clean hole with brush and pump.
3. Insert anchor through fi xture into hole and tap until required installation depth is
achieved.
4. Tighten to the recommended torque.