Warranties and Liabilities

 

 

1)  

The Company warrants that it has title to the Goods. 

 

2)  

Subject to the provisions of this clause the Company warrants that the Goods shall comply in all material 
respects  with  any  specification  referred  to  in  the  Order  Confirmation  (as  the  same  may  be  amended) 
and shall, subject thereto, be free from defects in material and workmanship for the lesser of a period of 
twelve months from the date of delivery or thirteen months from the date of dispatch from the factory. 

 

3)  

Save  as  provided  in  this  clause  and  except  where  the  Goods  are  sold  to  a  person  dealing  as  a 
consumer (within the meaning of the Unfair Contract Terms Act 1977) all warranties, conditions or other 
terms implied by statute or common law are hereby expressly excluded save to the extent they may not 
be  lawfully  excluded.      When  the  Goods  are  sold  to  a  consumer  within  the  meaning  of  the  Unfair 
Contract Terms Act 1977 their statutory rights are not affected by the provisions of this clause. 

 

4)  

In  the  event  of  the Customer making a claim in respect of  any  defect in terms of clause 2 hereof the 
Customer must:- 

 

4.1) 

reasonably satisfy the Company that the Goods have been properly installed, commissioned, 

stored,  serviced  and  used  and  without  prejudice  to  the  generality  of  the  foregoing  that  any 
defect is not the direct or indirect result of lack of repair and/or servicing, incorrect repair and/or 
servicing, use of wrong materials and/or incorrect spare parts; and 

4.2) 

allow the company to inspect the Goods and/or any installation and any relevant packaging 

as and when reasonably required by the Company. 

 

5)  

Subject  to  the  Company  being  notified  of  any  defect  as  is  referred  to  in  sub-clause  2  hereof  within  a 
reasonable  time  of  it  becoming  apparent  and  subject  always  to  the  terms of  sub-clause  4 hereof, the 
Company shall, in its option, replace or repair the defective Goods or refund a proportionate part of the 
Price.  The Company shall have no further liability to the Customer (save as mentioned in sub-clause 6 
hereof). 

 

6)  

The  Company shall be  liable to  indemnify the Customer in respect of  any claim for death  or personal 
injury to any person in so far as such is attributable to the negligence or breach of duty of the Company 
or any failure by the Company to comply with the provisions of sub-clause 2 hereof. 

 

7)  

Save as provided in sub-clause 2 hereof the Company shall not be liable in respect of any claim by the 
Customer for costs, damages, loss or expenses (whether direct, indirect, consequential or otherwise) or 
indemnity  in  any  respect  howsoever  arising  including,  but  not  by  way  of  limitation,  liability  arising  in 
negligence (other than pursuant to clause 6 above) that may be suffered by the Customer or any third 
party, 

SAFETY NOTICE TO USERS

 

 

 

These  instructions  must  be  read  thoroughly  and  understood  before  installation 
and operation of your Peak Gas Generator. Use of the Generator in a manner not 
specified  by  Peak  Scientific  Inst.  MAY  impair  the  SAFETY  provided  by  the 
equipment.  

 

When  handling,  operating  or  carrying  out  any  maintenance,  personnel  must 
employ  safe  engineering  practices  and  observe  all  relevant  local  health  and 
safety  requirements  and  regulations.  The  attention  of  UK  users  is  drawn  to  the 
Health  and  Safety  at  Work  Act  1974,  and  the  Institute  of  Electrical  Engineers 
regulations. 

 

Summary of Contents for ZA015

Page 1: ...as Generator ZA015 ZA180 Peak Scientific Instruments Ltd Fountain Crescent Inchinnan Business Park Inchinnan Renfrewshire PA4 9RE T Europe 44 0 141 812 8100 T USA 1 866 647 1649 sales T USA 1 866 732...

Page 2: ...Generator Instructions for use Manual 30th March 2005 ZA015 Issue 3 2 Document Change History Issue No Changed Initials Date 1 Document Created SGM 01 09 98 2 USA Technical support number updated FAD...

Page 3: ...Issue 3 3 Contents Page No Document History 2 Warranty Statement 5 Introduction 6 Unpacking Installation 6 Electrical Connection 6 Air Connection 7 Principle of Operation 8 Commissioning 9 Routine Mai...

Page 4: ...persons should operate or service this equipment Warning To avoid risk of electrical shock personal injury or death disconnect power before removing any cover of this equipment Caution To avoid risk o...

Page 5: ...he Goods and or any installation and any relevant packaging as and when reasonably required by the Company 5 Subject to the Company being notified of any defect as is referred to in sub clause 2 hereo...

Page 6: ...ould be taken not to obstruct the ventilation holes on the sides of the unit nor on the ZA180 the fan outlet on the top The generator should be placed on a steady and level base Alternatively the unit...

Page 7: ...isoned if it comes into contact with any halogenated hydrocarbons silicone sprays silicone greases phosphorous compounds lead components high sulphur vapours or other catalyst poisons The air supply s...

Page 8: ...isture and particles down to 0 1 micron The air is then passed to the Zero Air catalytic combustion chamber This works on the principle of catalytic oxidation where hydrocarbons from the incoming comp...

Page 9: ...r a period of time around 40 minutes the Catalytic Chamber should have reached the required temperature When this happens the relay on the Temperature Controller will click and the red LED will go out...

Page 10: ...increased levels of Hydrocarbons being detected on the baseline Reference to the following Fault Finder Chart will identify the source of the problem High CH4 Cat Chamber Hot Cold Control Board LED LE...

Page 11: ...5 3 5 7 0 18 0 Heater Watts 250 250 250 450 Fan Watts N A N A N A 9 0 Electrical Requirements 230V 50Hz 110V 60Hz 1 2A 2 3A 1 2A 2 3A 1 2A 2 3A 2 0A 4 5A Dimensions H x W x D cm Inches 51x25x16 20x10...