background image

Page 4

1x3m*

6mm OD x 4mm ID PE 00-1282

x1

UK Mains Cable C19 04-1025

x1

US Mains Cable C19  6-15 04-1024

x1

EU Mains Cable C19 04-1026

1/4

” Teflon Tubing 00-1266

2x3m*

Fittings Kit

x2*

1/4

” Compression Fitting 

02-4421

x1*

1/4

”  - 6mm Push Fit Fitting 

02-4600

x3*

Flow Control SIlencer 02-1096

* MS Bench G SCI 1 & G SCI 2 Only

** MS Bench SCI 1 & SCI 2 Only

x1**

US Mains Cable 120V C19  5-15 04-1035

x1*

5/16

” Compression Fitting 

3303538

5/16

” Teflon Tubing 3303537

1x3m*

Summary of Contents for MS Bench

Page 1: ...MS Bench All Models Installation Guide Rev 5 RSID 3024 IG 0028 EN 24 08 20 MS Bench All Models Installation Guide...

Page 2: ...acilitate safe and correct installation and initial configuration of your Peak Scientific gas generator For more extensive user operation directions we recommend you download the User Manual from the...

Page 3: ...ed to could cause damage to the Generator or the Application Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood or met Caution risk of electric shock Ensure pow...

Page 4: ...19 04 1026 1 4 Teflon Tubing 00 1266 2x3m Fittings Kit x2 1 4 Compression Fitting 02 4421 x1 1 4 6mm Push Fit Fitting 02 4600 x3 Flow Control SIlencer 02 1096 MS Bench G SCI 1 G SCI 2 Only MS Bench SC...

Page 5: ...ack the generator from the shipping crate and position on a flat surface in desired area 1 2 To extend the levelling feet first pull the ratchet handle out There is a ring pull on the handle to aid re...

Page 6: ...on the end of the tab Pressing this will reverse the direction of the ratchet mechanism ratcheting to the left will then raise the foot from the floor 4 With the foot in position push the tab back in...

Page 7: ...trol Silencer 02 1096 fittings to the Curtain Source Exhaust Ports 02 4600 02 4600 02 1096 02 1096 There are Transit Bolts located on the underside of the generator The G SCI 1 has 2 bolts and the G S...

Page 8: ...the cable into the mains input at the rear of the generator Connect the 6mm PE Tubing 00 1282 to the 6mm Push Fit Fitting 02 4600 Fit the other end of the tubing to a suitable drain connection or con...

Page 9: ...10 MS Bench G SCI 1 G SCI 2 100 240v 10 MS Bench SCI 1 SCI 2 single phase power supply CAUTION ensure the correct cable has been selected for your electrical supply UK EU US 230V CAUTION Switch the ge...

Page 10: ...el and check gauges have risen to the factory set pressures stated in the User Manual The gauges are located in the bottom left hand corner of the G SCI 1 For G SCI 2 models the gauges are located beh...

Page 11: ...Page 11 14 13 Switch the generator power OFF using the switch on the front panel The purge is now completed and the silencer fittings can be removed from the Curtain Source Exhaust ports...

Page 12: ...o the fittings attached to the SOURCE EXHAUST Connect the other end of the tubing to the corresponding gas inlets of your instrument 00 1266 00 1266 Select the 5 16 Compression Fitting 3303538 1 4 Com...

Page 13: ...Page 13 18 17 CONGRATULATIONS Your Peak Scientific MS Bench is now fully installed and operational Switch the generator power ON using the switch on the rear panel...

Page 14: ...erator is to be installed further away from the instrument then attention needs to be paid to pressure drops that could occur The maximum distance away from the instrument the generator can be placed...

Page 15: ...ic com For generators that remain unregistered after 1 month from the shipment date the warranty will be considered active from the date of factory dispatch Complete Plan only Go Online or Complete an...

Page 16: ...All Models Installation Guide Rev 5 RSID 3024 IG 0028 EN 24 08 20 Peak Scientific has highly trained fully certified Field Service Engineers located in over 20 countries across every continent around...