![PDR D2 Operator'S Manual Download Page 20](http://html.mh-extra.com/html/pdr/d2/d2_operators-manual_1516834020.webp)
www.pdr-rework.com
The system steps through the stages/zones (preheat/reflow/soak etc) based on a time, i.e. there is a clock ticking and
the cycle progresses through the profile irrespective of the temperature reached.
Control and Settings (continued)
Default Profiles
To help, we have included various default profiles to try out with the software control. We strongly recommend you
open a default profile... Auto Mode...and practice rework on dummy boards and components before launching into
action on your live PCBs.
Profiles that you develop will probably not vary very much from original defaults and they generate better
understanding of reworking with the PDR Rework system. For more detailed technical information contact your PDR
representative for help.
Settings Screen
Control Mode
Settings Screen Tab
Wait for PCB Temp
Preheater Zone 2 on/off
Software Lock/Unlock