READ AND FOLLOW
ALL INSTRUCTIONS!!
This unit is a professional-grade product. A knowledge of construction
techniques, plumbing and electrical installation according to codes are required
for proper installation and user satisfaction. It is recommended that a licensed
contractor perform the installation. Warranty is voided
for improper Installation related issues.
It is the responsibility of the home owner to ensure that all users of the spa are adequately
informed of all precautions.
Use the spa only as described in this manual. The spa is intended for home use only. Do not use
the spa in a commercial or rental setting. All warranties will be voided.
GROUND ALL METAL ELECTRICAL EQUIPMENT
A green colored terminal or a terminal marked G, GR, Ground, or Grounding, is located
inside the supply terminal box or compartment. This terminal must be connected to the
grounding means provided in the electric supply service panel, using a continuous copper wire
equivalent in size to the circuit conductors supplying this equipment. *
according to, but not limited
to: NEC, NFPA 70, Section 680.40, UL 1563., CAN/CSA C22.2 No. 281.1M89
At least two lugs marked “Bonding Lugs” are provided on the external surface or on the
inside of the supply terminal box or compartment. Connect the local common bonding grid
(household ground) in the area of the spa to these terminals, using an insulated or bare
copper conductor not smaller than No. 6 AWG.
All field-installed metal components such as rails, ladders, drains or similar hardware
located within 5 feet (1.52 m) of the spa or hot tub must be bonded to the equipment grounding
bus with copper conductors not smaller than No. 6 AWG.
All metal surfaces within 5 feet (1.52 m) of spa must be bonded to the home bonding grid.
GROUND FAULT CIRCUIT INTERRUPTER PROTECTION
(
OR EQUIVALENT; RCD, FOR EXPORT INSTALLS
)
All PDC Spas are permanently installed units. GROUND FAULT CIRCUIT INTERRUPTER
PROTECTION IS REQUIRED. All spa equipment systems must be protected by a class a
ground fault circuit interrupter (GFCI) or equivalent; RCD, for export installs. A ground
fault circuit interrupter type circuit breaker (NOT SUPPLIED) must be installed in the home
panel box by a licensed electrician when making wire connection to the spa support pack equip-
ment.
DANGER: RISK OF ELECTRICAL SHOCK:
Install the spa at least five feet (1.52 m) from all ungrounded (unbounded) metal surfaces.
Ground fault circuit interrupter protection of the home power supply to the spa is necessary.
Your electrician should explain how it works. (See spa maintenance)
Do not permit any electric appliance, such as a light, telephone, radio or television, within five
feet (1.52 m) of a spa. Keep electrical appliances and extension cords away from the spa.
Water is a conductor of electricity.
READ AND FOLLOW ALL IMPORTANT SAFETY INSTRUCTIONS
When installing and using this equipment basic safety precautions should always be taken to
reduce the risk of electrical shock, to ensure safe usage, and to safeguard the user’s health.