CONFIGURING the IN.XM CE
29
Use
Change
button to go from one
parameter to the next.
Press Select button again to make the
correct selection.
All receptacles will match the corre-
sponding female connection on the
spa pack.
No connections should remain
unplugged. Use blank plugs to fill
unused connectors.
Make sure all accessories are linked to
the bonding connector and connected
to pack.
Make sure the spa pack door is closed.
Turn on the breaker.
It is important to specify the phase
configuration setting at the power
supply: single phase (1P), dual phase
(2P), or three phase (3P)
(see configuration below)
Case 1
Single-phase 1 x 230 V~
(32 A max)
The installation of electrical
circuit jumpers is needed in
certain input supply
configurations.
Use uncut jumper as supplied
in the case of an input supply
wiring,
Case 2
Dual-phase 1 x 230 V~
(2 x 16 A max)
For this input supply wiring,
you will need to cut off a
portion of jumper piece.
Proceed as follows:
Use pliers to firmly hold upper
half of the metal jumper, then
break off other half.
Case 3
Three-phase 1 x 230 V~
(3 x 16 A max)
Please note that in a three-
phase system , no jumper
installation is required.
Important!
Safely dispose of the discarded
portion in accordance with the
local waste disposal legislation
in force.
Description:
Phase setting appears (P) at power up. Press
Change
button to choose proper phase setting. Press
Select
button to lock in
proper phase. Breaker setting appears (BR). Press
Change
button to choose proper breaker setting.
Select
button is used to access the phase
configuration setting menu (short press) as well as the low level programming menu (press and hold for 5 seconds). Subsequent presses will
save changes and display the next option available or exit automatically if it was the last one. Use
Change
button to change the parameters
displayed. Note: this procedure has to be performed after every learning mode.
Setting the Learning Mode:
The in.xm.ce pack has the ability to verify and “learn” the current consumption of every output connected to it.
If an output is replaced, a new learning must be done. Follow these simple steps.
Press and hold
Select
button for 5 seconds to activate low level programming. Once activated, the display shows “LL” ad, I succession, the
current preset low level configuration selected.
Press
Change
button repeatedly to select the same preset low level configuration again.
Press
Select
to confirm. You will exit menu automatically. The in.xm.ce will then reset. After resetting, the system starts a “learning se-
quence” in which each individual output is activated and its peak current displayed and saved.
Note:
if unusual current readings, e.g. 4 to 6 amps are detected on high speed of any pump, all pumps must be primed, learning mode restarted.
Press
Select
button to select
proper phase configuration set-
ting. The in.scan display will
show “xP”, with “X” represent-
ing the number of phases of the
electric power system.
RCD Br
1X32A 1P
2X16A 2P
3X16A 3P
LOW LEVEL SPA
CONFIGURATION COMPONENT
PUMP1 PUMP2 PUMP3 BLOWER
LL1
X
LL2
X X
LL3
X X X
LL4
X X X X
NOTE: Low level programming (LL) has been factory
preset. In the course of setting the incoming power should
“LL” be shown on screen, there should be no changes
made to this setting. Immediately exit the LL menu by
pushing the select button. If the LL configuration was
changed, refer to chart above to review proper LL settings.
Wiring Installation—EXPORT GUIDELINES in.xm ce
POWERING UP the IN.XM CE