less than 3 seconds. The RCD-Test LED
indicator on the tester should illuminate. If the
RCD switch got triggered and all LED lights of
the tester are off, the RCD switch functions
properly. Please reset the RCD switch and
remove the tester. If the RCD switch was not
triggered, than the RCD switch does not function
properly. Please consult with a professional
electrician.
Technical Specifications:
Operating Voltage
48~250V / 45~65Hz
Measurement Range
48~250V/45~65Hz
Accuracy: ± (2.0%+2)
Operating Temperature
0°C~40°C
Operating Humidity
20%~75%RH
Storage Temperature
-10°C~50°C
Storage Humidity
20%~80%RH
Altitude
≤2000m
RCD Test
>30mA
RCD Working Voltage
220V±20V
Safety
CE, CAT.II 300V
Cleaning
Use a dry or slightly damp cloth for cleaning,
never use chemicals or detergents.
Caution:
Make sure that the device is completely dry,
before continuing to use it.
Information regarding waste disposal:
You are not permitted to dispose of this device in
household garbage. This multimeter corresponds
to the EU-directive concerning the “Waste of
Electrical and Electronic Equipment”. Please
dispose of the device in your local collection
point.
Creation date of manual: March 2021 – all
technical changes reserved. No responsibility is
taken for any technical or printing errors.