<TEMP ALARM>
You can set the sensitivity of temperature alarm here. We recommend you set these to 70-80 degrees Celsius. A properly
installed unit with a tiny fan will typically run at 55 degrees C at maximum output power. This alarm applies to externally
sensed temperature if you are using external filter or directional coupler connected via DIGIAMP.
Fig. 9: Temperature alarm.
<SWR ALARM>
You can set the sensitivity of software driven SWR alarm here.
Fig. 10: Temperature alarm
<U AMP ALARM>
You can set the sensitivity of amplifier supply voltage alarm here. We recommend you set these according to your amplifier.
Usually this is around 50V. This alarm only works if you use PCS LPF 6000/7000 filters with voltage sensor.
Fig. 11: Amplifier voltage alarm
<DRIVE LIMIT>
You can set the level of input drive at which the gain of amplifier will fall once this level is reached. This can help protect
against excessive driving of amplifier.
Fig. 12: Drive power limit