MOST 20-2B
8
PACIFIC CONSOLIDATED INDUSTRIES
350003 Rev D
ITEM DESCRIPTION
1
CYLINDER CONTENTS GAUGE P1-1:
Direct reading of the pressure in all
cylinders. Pressure automatically
equalized between cylinders.
2
VENT VALVE V-3: Controls release of
pressure from filling circuit. When filling
the valve is set to close and when venting
is set to vent.
3
OXYGEN INPUT C-4: High pressure,
self-sealing, quick disconnect fitting for
refilling MOST cylinders.
4
OUTPUT PRESSURE P1-3: Direct
reading gauge showing oxygen pressure
being delivered to the three OXYGEN
OUTPUT ports.
5
OXYGEN OUTPUT C-1, C-2 & C-3:
Self-sealing, quick connect fittings for
connection of the green oxygen delivery
hoses.
6
VENT F-2: Vents excess pressure from
RV-1, RV-2 and V-3
MOST Operating Panel