PCE Instruments PCE-VC20 User Manual Download Page 9

 

 

©  PCE Instruments 

 

Warranty 

You  can  read  our  warranty  terms  in  our  General  Business  Terms  which  you  can  find  here: 

https://www.pce-instruments.com/english/terms

 

Disposal 

For  the  disposal  of  batteries  in  the  EU,  the  2006/66/EC

 

directive  of  the  European  Parliament 

applies. Due to the contained pollutants, batteries must not be disposed of as household waste. 
They must be given to collection points designed for that purpose. 
 
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use 
them or give them to a recycling company which disposes of the devices in line with law.  
 
For countries  outside the EU,  batteries  and  devices should  be  disposed  of in  accordance  with 
your local waste regulations. 
 
If you have any questions, please contact PCE Instruments. 
 

 

 
 
 
 

 

Summary of Contents for PCE-VC20

Page 1: ...ibration Process Calibrator User Manual User manuals in various languages Deutsch fran ais italiano espa ol portugu s nederlands t rk polski can be downloaded here www pce instruments com Last change...

Page 2: ...fety notes 1 2 Specifications 2 3 System description 3 4 Purpose 3 5 Properties 3 6 Operation 4 6 1 Attaching the Test Object 4 6 2 Calibration 5 6 3 Changing the Accumulator 6 6 4 Reset 6 7 Calibrati...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...10 N Max torque 2 Nm Nominal torque 1 Nm Max transverse force 20 Nm Transverse vibration 10 of main axis measured 14 mm above shaker Mounting of test object M5 tapped hole 7 mm deep Clamping magnet A...

Page 5: ...installations Fault finding 5 Properties Handy and robust battery device for laboratory and field use Load independent vibration magnitude with and field use 10 m s 2 vibration acceleration 10 mm s v...

Page 6: ...ransport 6 Operation 6 1 Attaching the Test Object The Vibration exciter of the PCE VC20 has a tapped M5 hole with 7 mm depth for the attachment of the device under test The supplied stud bolts and st...

Page 7: ...If the absolute error exceeds 3 the percent value will change to inverse characters and a beep sound will be generated In this case no calibration can be performed When the maximum weight of the test...

Page 8: ...emory effect Partial charging is permissible Permanent connection of the mains adapter is not recommended This may lead to premature wear of the battery In order to avoid overcharging the battery it i...

Page 9: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Page 10: ...583 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english w...

Reviews: