PCE Instruments PCE-TC 30N User Manual Download Page 19

 

 

©  PCE Instruments 

17 

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 4 

23, rue de Strasbourg 

Calle Mayor, 53 

D-59872 Meschede 

67250 Soultz-Sous-Forets 

02500 Tobarra (Albacete) 

Deutschland 

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 

 

 

United Kingdom 

Italy 

Turkey 

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

PCE Teknik Cihazları Ltd.Şti. 

Unit 11 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Halkalı Merkez Mah. 

Ensign Way, Southampton 

55010 Loc. Gragnano 

Pehlivan Sok. No.6/C 

Hampshire  

Capannori (Lucca) 

34303 Küçükçekmece - 

İstanbul 

United Kingdom, SO31 4RF 

Italia 

Türkiye 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Tel: 0212 471 11 47 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

Faks: 0212 705 53 93 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

www.pce-instruments.com/turkish 

 

 

 

The Netherlands 

Hong Kong 

United States of America 

PCE Brookhuis B.V. 

PCE Instruments HK Ltd. 

PCE Americas Inc. 

Institutenweg 15 

Unit J, 21/F., COS Centre 

1201 Jupiter Park Drive, Suite 8 

7521 PH Enschede 

56 Tsun Yip Street 

Jupiter / Palm Beach 

Nederland 

Kwun Tong 

33458 FL 

Telefoon: +31 (0)53 737 01 92 

Kowloon, Hong Kong 

USA 

[email protected] 

Tel: +852-301-84912 

Tel: +1 (561) 320-9162 

www.pce-instruments.com/dutch 

[email protected] 

Fax: +1 (561) 320-9176 

 

   

www.pce-instruments.cn 

[email protected] 

 

 
 

 

 

Summary of Contents for PCE-TC 30N

Page 1: ...rmal Imaging Camera User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last ch...

Page 2: ...scope 3 3 System description 4 3 1 Device 4 3 2 Getting started 5 3 3 Display description 6 3 4 Control panel 7 4 Menu 8 4 1 Image overlapping 8 4 2 Show saved images 8 4 3 Colour palettes 9 4 4 Emiss...

Page 3: ...ice The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner no abrasives or solvents The device must only be used with accessories from PCE Instruments or equivalent Before...

Page 4: ...Hz Colour palettes Spectrum Iron Cold White Black Emissivity Variable 0 01 1 0 Memory Image memory Internal SD card 3 GB for more than 20000 images Image format JPG Settings Setting options Automatic...

Page 5: ...PCE Instruments 3 2 2 Delivery scope 1 x thermal imaging camera PCE TC 30N 1 x USB cable 1 x USB mains adaptor 1 x user manual 1 x carrying bag...

Page 6: ...description 3 1 Device 1 Display 2 control panel 3 Handle 6 Micro USB connector under protective cap 7 infrared bolometer 8 Digital camera 9 LED light 10 Save screen capture switch LED on or off 11 In...

Page 7: ...the battery level is low this is indicated by the symbol at the top right of the screen Charge the thermal imaging camera via the micro USB interface To do this proceed as follows Connect the supplied...

Page 8: ...cus of the thermal imaging camera 3 3 3 Maximum temperature in the current image section The red mark appears where the highest temperature is measured in the current image section At the same time th...

Page 9: ...era In this way measured objects can be clearly assigned The overlapping can be adjusted in 25 steps by pressing the left or right navigation key in normal measuring mode 3 4 4 Saving images To do thi...

Page 10: ...s otherwise no digital image may be recognisable Furthermore the exact positioning of the infrared image depends on the distance of the object to be examined 4 2 Show saved images Open the menu with t...

Page 11: ...ed palette should be selected See several example images with the respective colour palettes below Rainbow Iron Cold White Black 4 3 1 Set colour palette Open the menu using the menu key and use the n...

Page 12: ...n key on the right takes you to the submenu Here all available emissivities are displayed in a list The following functions are available 4 standard emissivities are available matt e 0 95 semi matt e...

Page 13: ...k 0 93 0 96 Textile 0 90 4 5 Settings Open the menu using the menu key and use the navigation keys up or down to highlight the menu item Setting Pressing the navigation key on the right takes you to t...

Page 14: ...highlight the menu item Language Pressing the navigation key on the right takes you to the submenu All available settings are displayed here in a list Navigation key up or down scroll through the list...

Page 15: ...e submenu All available settings are displayed here in a list Navigation key up or down scroll through the list Select enter key edit current selection Navigation key up or down change number at marke...

Page 16: ...em Cold hotspot Pressing the navigation key on the right takes you to the submenu All available settings are displayed here in a list Navigation key up or down scroll through the list Select enter key...

Page 17: ...eshooting The following problems may occur during operation of the thermal imaging camera If the suggested solutions are not helpful please contact PCE Instruments Problem Cause Solution The thermal i...

Page 18: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 19: ...Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 05...

Reviews: