background image

 

reading. Press again to unlock display. 

 

5.4 Max/Min 

Press the MAX/MIN key and the reading will 
change from max,min,normal. 

Press and hold the MAX/MIN button for about 3 
seconds to clear and Stop the MAX/MIN/ 
recording.

 

5.5 Measuring m/s,ft/min,km/h,MPH,knots     

Press the UINTS key and the reading will 
change from m/s,ft/min,km/h,

MPH

KNOTS

 

5.6 Select temperature units 

  OR 

Turn  on  the meter first.  Press  the UINTS 
buttons  and hold about for 3 seconds  to 
change temperature units. 

 

5.7 The BACKLIGHT ON and OFF 

Press and hold the HOLD key about for 3 
seconds to turn on or off the backlight. 
 

Summary of Contents for PCE-TA 30

Page 1: ...on PCE Americas Inc 711 Commerce Way Suite 8 Jupiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE...

Page 2: ...ble service 2 Features 2 1 Air Velocity and Temperature measurements displayed on multi function 2 2 Full 4 digit display of air velocity in m s ft min km h MPH and knots 2 3 C F Temperature measureme...

Page 3: ...low Air Flow Range Resolution Area CFM 0 999 900 ft3 min 0 1 0 999 9ft2 Air Velocity Units Range Resolution Accuracy m s 1 00 30 00 0 01 3 0 20 m s ft min 196 5900 1 3 40 ft min km h 3 6 108 0 0 1 3 0...

Page 4: ...0 0 1 3 0 F Dimensions 163 x 45 x 34 mm Display size 26 7 x 25 4 mm Fan Diameter 27 2 mm Whight 257 g 4 Meter Description 1 Vane impeller 2 Precision thermister 3 LCD display 4 Power key 5 Hold key Ba...

Page 5: ...BYPASS AUTO POWER OFF The meter will automatically turn off after 15 minutes in the normal When you turn on the meter and press the button UNITS first an disAP0 appears on the LCD then you can release...

Page 6: ...top the MAX MIN recording 5 5 Measuring m s ft min km h MPH knots Press the UINTS key and the reading will change from m s ft min km h MPH KNOTS 5 6 Select temperature units OR Turn on the meter first...

Page 7: ...y and hold 3 Turn on the meter then the meter will be into area set mode and the set area show on the LCD 4 Press the MAX MIN key to shift the radix point 5 Press the HOLD key to shift the flash posit...