background image

Manual 

 
 

15 

 

 

15  Contact 

If you have any questions about our range of products or measuring instruments please contact PCE 
Instruments. 

15.1  PCE Instruments UK 

By post: 

PCE Instruments UK Ltd. 
Units 12/13 Southpoint Business Park 
Ensign Way, Southampton 
Hampshire 
 
United Kingdom, SO31 4RF 
 

By phone:

 

02380 987 035 
 

15.2  PCE Americas 

By post: 

PCE Americas Inc. 
711 Commerce Way 
Suite 8 
Jupiter 
33458 FL 
USA 
 

By phone:

 

561 320 9162 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

 

 

Summary of Contents for PCE-T 390

Page 1: ...ts UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampton United Kingdom SO31 4RF From outside UK 44 Tel 0 2380 98703 0 Fax 0 2380 98703 9 info pce instruments com www pce instru...

Page 2: ...alogger 9 7 Saving data from the SD card to the computer EXCEL software 10 8 Advanced settings 10 9 Power supply from DC adaptor 11 10 Battery replacement 11 11 RS232 PC serial interface 11 12 Offset...

Page 3: ...ssible Data hold records max and min reading High accuracy Power by UM3 AA 1 5 V x 6 batteries or DC 9V adapter RS232 USB PC COMPUTER interface 2 Safety notes Please read this manual carefully and com...

Page 4: ...1 C 0 1 F 1 C Datalogger Sampling time Setting range Auto 1 second to 3600 seconds Sampling time can be set to 1 second but memory data may get lost Manual Pushing the datalogger button once will save...

Page 5: ...r manual off by pushing button Operating temperature 0 50 C Operating humidity Less than 85 RH Power supply Alkaline or heavy duty DC 1 5 V battery UM3 AA x 6 pcs or equivalent DC 9V adaptor input AC...

Page 6: ...0 2102 F 0 4 2 F T type 0 1 C 50 1 100 0 C 0 4 1 C 50 0 400 0 C 0 4 0 5 C 0 1 F 58 1 148 0 F 0 4 1 8 F 58 0 752 0 F 0 4 1 F E type 0 1 C 50 1 100 0 C 0 4 1 C 50 0 900 0 C 0 4 0 5 C 0 1 F 58 1 148 0 F...

Page 7: ...on button R button 4 7 SET button time check button 4 8 Logger button OFFSET button sampling time check button 4 9 T1 T2 T3 T4 input socket type K type J 4 10 PT1 input socket Pt 100 Ohm 4 11 PT2 inpu...

Page 8: ...t 100 Ohm measurement only allows max two channels two probes to be used T1 T2 measurement If two probes are inserted type K J T E R S use T1 T2 input socket Pt 100 Ohm use PT1 PT2 input socket When y...

Page 9: ...the datalogger function will be paused stop to save the measuring data into the memory circuit temporarily REC will stop flashing Note If you press the Logger Button 4 8 once again the datalogger fun...

Page 10: ...al times to select one of the seven main functions The lower display will show dAtE Set clock time year month date hour minute second dEC Set SD card decimal character PoFF Auto power OFF management b...

Page 11: ...utton 4 5 or the Button 4 6 to set the upper value to yES or no yES to format the SD memory card no not format the SD memory card 2 If you select yES press the Enter Button 4 4 once again The display...

Page 12: ...egative D9 Decimal point DP position from right to left 0 no DP 1 1 DP 2 2 DP 3 3 DP D8 to D1 Display reading D1 LSD D8 MSD e g if the display reading is 1234 then D8 to D1 is 00001234 D0 End Word RS2...

Page 13: ...least two seconds then release it The display will show 4 If you wish to make the offset adjustment for Pt 1 insert the probe into the PT1 input socket Press the L button 4 5 once so that the display...

Page 14: ...0 cm tube 3 2 mm Thermocouple probe Type K TP 03 Meas range 50 1200 C 50 2200 F Dimensions 10 cm tube 8 mm Surface probe Type K TP 04 Meas range 50 400 C 50 752 F Dimensions temp sensing head 15 mm Pr...

Page 15: ...contact PCE Instruments 15 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 15 2...

Reviews: