Introduction
Thank you for purchasing a machine PCE-S 42 from PCE Instruments.
This electronic stethoscope is a new high-performance maintenance tool as well as an economic
instrument used to locate bearing or mechanical noises. It is particularly applicable to use in a noisy
environment to detect and maintain hidden trouble of equipment at its early stage, so that the normal
operation of equipment can be assured and the huge economic losses arising from equipment breakdown
can thus be avoided.
The electronic stethoscope is supplied with a highly sensitive probe which can effectively locate the parts
of the machine where the noises come from, such as the trembling sounds of valve tremor, tappet
vibration, loose piston, vibrations of gears and pumps, even the noise from the operation of the solenoid
of relay. Moreover, it can also detect and monitor the flow and clogging of liquid, operating status of all
kinds of motors, internal-combustion engines, diesel engines, engines and domestic appliances, as well
as the running state of automatic running water system in industrial and mining enterprises.
It is widely applied in the watercraft industry, automobile industry, chemical industry, metallurgy industry,
machine tools, household electrical appliances and machinery industry.
2
Safety notes
Keep the probe and stethoscope head far away from rotating objects.
Please read this manual carefully and completely before you use the device for the first time. The device
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no
warranty of damages or injuries caused by non-observance of the manual.
- The device may only be used in the approved temperature range.
-
The case should only be opened by qualified personnel of PCE Instruments.
- The instrument should never be placed with the user interface facing an object (e.g. keyboard side on
a table).
- You must not make any technical changes to the device.
- The appliance should only be cleaned with a damp cloth / use only pH-neutral cleaner.
This user manual is published by PCE Instruments without any guarantee.
We expressly point to our general guarantee terms which can be found in our general terms of business.
If you have any questions please contact PCE Instruments.
3
Specification
Frequency range
30 Hz … 15 KHz
Operating temperature
-
10 … +45 °C
Output volume
digital adjustment (32 grades)
Headphones
32
Ω
Battery
4 x AAA batteries
Battery life
approx. 30 h
Dimensions
220 x 35 x 35 mm
Probe size
280 & 70 mm