1.  Safety Precautions 

Please read the following instruction manual before operating with the device. Damages caused by 
disregard of the instructions written in this manual, are excluded from any warranty or liability.

 

This device is only designed for the applications mentioned in this manual. In case the 
device is used for any other application than these, it might lead to hazardous situations. 

The device is can only be used within the permitted temperature range. 

The sensor must be stored in the carrying case included in delivery, if not used. 

Let the device prior to application acclimate to the surrounding temperature 

The device may be opened only by specialized personnel of PCE instruments 

Never set down the device on its control panel (e.g. onto a table, with the console faced 
down). 

The device should be only cleaned with a damp cloth. Do only use pH-neutral solvents. 

 

2.  Technical Specifications 

Measurement geometry:  

45°  /  0°  circular  lighting  at  45°, measurement  at 0°  according  to DIN 
5033 

Measurement range:   

RGB: 0 … 1023 each for, R, G and B / HSL 0 … 1,000 for H, S, L 

Resolution: 

 

 

1 for RGB measurement / at 0.001 HSL-measurement 

Repeatability:    

 

< 3 RGB, at min. 10 measurements 

Colour models:  

 

RGB and HSL 

Spectral range: 

 

400 nm up to 700 nm 

Light source:   

 

2 white light diodes 

 

 

 

 

Caution: The device can be only operated with non-fluorescent 

sensors 

Applications:    

 

- not for illuminated surfaces (absolute values) 

 

 

 

 

- for self-luminous surfaces (relatively compared) 

Display: 

 

 

Relative and absolute values 

Interface: 

 

 

RS-232 at display 

Software: 

 

 

Optional software kit  

Power Supply:  

 

1 x 9 V bloc battery 

Dimensions (sensor):   

45 x 92 x 160 mm 

Weight:  

 

 

approx.. 600 g 

Surrounding conditions: 

0 … +50 °C / max. 80 % RH 

Standards: 

 

 

DIN 5033 

 
 

 

Summary of Contents for PCE-RGB 2

Page 1: ...9 2014 www industrial needs com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southhampton Hampshire United Kingdom SO31 4RF Phone 44 0 2380 98703 0 Fax 44 0 2380 98703 9 info...

Page 2: ...ical Specifications 2 3 Detailed description of device 3 4 Measuring Procedure 3 4 1 Measurement of samples that are not self luminous 3 4 2 Measurement on self luminous samples 4 4 3 Relative measure...

Page 3: ...on its control panel e g onto a table with the console faced down The device should be only cleaned with a damp cloth Do only use pH neutral solvents 2 Technical Specifications Measurement geometry 4...

Page 4: ...Input sensor 4 18 Connector 4 Measuring Procedure 4 1 Measurement of samples that are not self luminous Materials that do not luminaire on their own are e g paper leather synthetics Insert the Connect...

Page 5: ...for application on self luminous surfaces 4 2 Measurement on self luminous samples Self luminous materials are e g LCD monitors LED s Consider for this measurement mode that there might appear larger...

Page 6: ...lf luminous samples The delivery also contains a standard white which represents the 100 white value not optically lightened That standard is a white paper But you can also use other commercial standa...

Page 7: ...o so Reattach the cover of the battery compartment and secure with the screws 8 Software The software of the colour meter PCE RGB 2 can be purchased optionally The delivery of the software will contai...

Reviews: