Repeat Format
How the stepping should be done.
Available Options:
UP
DOWN
UP/DOWN
DOWN/UP
This parameter is enabled only for Auto Step Mode (Manual CheckBox is
Un-Checked)
Repeat
Repeat Counts
Defines how many times the steps are repeated
Range:
1 to 9999
This parameter is enabled only for Auto Step Mode (Manual CheckBox is
Un-Checked)
Manual Stepping
To Enable Manual Stepping, select Source Type as STEP and Check the Manual CheckBox.
If this mode is enabled,
icon will appear in Source Display Window in RUN Page.
Pressing UP or DOWN key in RUN Page will increase or decrease Source Value by Step Size
specified in STEP Page.
In RUN Page, Source Value can directly change by Pressing
F1
key (EDIT) and modifying value
like in EditBox. and STEP Setting can be accessed directly by
F2
key (SETTING).
Auto Stepping
To Enable Auto Stepping, select Source Type as STEP & Un-Check the Manual CheckBox.
If this mode is enabled,
(Step UP) or
(Step Down) icon will appear in Source Display
Window in RUN Page and F1 and F2 Button change to
START
and
SETTING
respectively.
Automated Step can be started by Pressing
F1
key (START). After that F1 and F2 key will change
to
PAUSE
and
STOP
respectively. So by pressing F1 and F2 key running STEP can be PAUSE
or STOP at any time in RUN Page.
STEP Setting can be accessed directly by
F2
key (SETTING).