background image

 

 

 

©  PCE Instruments 

26 

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 4 

23, rue de Strasbourg 

Calle Mayor, 53 

D-59872 Meschede 

67250 Soultz-Sous-Forets 

02500 Tobarra (Albacete) 

Deutschland 

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 

 

 

Germany 

United Kingdom 

Italy 

Produktions- und  

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

Entwicklungsgesellschaft mbH 

Units 11 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Im Langel 26 

Ensign Way, Southampton 

55010 Loc. Gragnano 

D-59872 Meschede 

Hampshire  

Capannori (Lucca) 

Deutschland 

United Kingdom, SO31 4RF 

Italia 

Tel.: +49 (0) 2903 976 99 471 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Fax: +49 (0) 2903 976 99 9971 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

 

 

 

The Netherlands 

Chile 

Hong Kong 

PCE Brookhuis B.V. 

PCE Instruments Chile S.A. 

PCE Instruments HK Ltd. 

Institutenweg 15 

RUT: 76.154.057-2 

Unit J, 21/F., COS Centre 

7521 PH Enschede 

Calle Santos Dumont  N° 738, Local 4  

56 Tsun Yip Street 

Nederland 

Comuna de Recoleta, Santiago 

Kwun Tong 

Telefoon: +31 (0)53 737 01 92 

Tel. : +56 2 24053238 

Kowloon, Hong Kong 

Fax: +31 53 430 36 46   

Fax: +56 2 2873 3777 

Tel: +852-301-84912 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/dutch 

www.pce-instruments.com/chile 

www.pce-instruments.cn 

 

 

 

United States of America 

Turkey 

China 

PCE Americas Inc. 

PCE Teknik Cihazları Ltd.Şti. 

PCE

 (Beijing) 

Technology Co

., 

Limited 

711 Commerce Way suite 8 

Halkalı Merkez Mah. 

1519 Room, 6 Building 

Jupiter / Palm Beach 

Pehlivan Sok. No.6/C 

Zhong Ang Times Plaza 

33458 FL  

34303 Küçükçekmece - 

İstanbul 

No. 9 Mentougou Road, Tou Gou District

 

USA   

Türkiye 

102300 Beijing 

Tel: +1 (561) 320-9162 

Tel: 0212 471 11 47 

China 

Fax: +1 (561) 320-9176 

Faks: 0212 705 53 93 

Tel: +86 (10) 8893 9660 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/us 

www.pce-instruments.com/turkish 

www.pce-instruments.cn 

 
 

 

 

Summary of Contents for PCE-ITM 20

Page 1: ...lation Meter PCE ITM 20 PCE ITM 20 User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last...

Page 2: ...ents 10 3 7 Continuity Check 11 3 8 Diode Test 12 3 9 Capacitance Measurements 12 3 10 Temperature Measurements 13 3 11 Frequency Duty Cycle Measurements electronic 13 3 12 4 20mA Measurements 14 3 13...

Page 3: ...PCE Instruments 4 Maintenance 19 4 1 Battery Installation 19 4 2 Replacing the Fuses 20 5 Technical specifications 20 6 Test method of DAR and PI 24 7 Warranty 25 8 Disposal 25...

Page 4: ......

Page 5: ...he specifications must not be exceeded under any circumstances NEVER apply voltage or current to the meter that exceeds the specified maximum Input Protection Limits Function Maximum input V DC or V A...

Page 6: ...round exceeds 1000 VAC or VDC This symbol adjacent to one or more terminals identifies them as being associated with ranges that may in normal use be subject to particularly hazardous voltages For max...

Page 7: ...ETUP button 5 MODE LOCK button 6 INSULATION TEST button 7 Function switch 8 10 A input jacks 9 mA A and insulation input jacks 10 COM input jack 11 Positive input jack 12 Backlight button 13 EXIT AC D...

Page 8: ...3 volts amps Amps kilo 103 ohms Farads capacitance mega 106 ohms Ohms Peak Hold Hertz frequency Volts Per cent duty ratio Relative Alternating current Autoranging Direct current Display hold Degrees F...

Page 9: ...ation Risk of electrocution High voltage circuits both AC and DC are very dangerous and should be measured with great care ALWAYS turn the function switch to the OFF position when the meter is not in...

Page 10: ...ur that can damage the meter Set the function switch to the green VAC Hz position Insert the black test lead banana plug into the negative COM jack Insert red test lead banana plug into the positive V...

Page 11: ...ate DC or AC or in AC range press EXIT for two seconds and choose AC DC Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive V jack...

Page 12: ...500 mA DC set the function switch to the yellow mA position and insert the red test lead banana plug into the A mA jack For current measurements up to 20 A DC set the function switch to the yellow 10...

Page 13: ...he red test lead banana plug into the 10A jack Press the MODE button to indicate AC on the display Remove power from the circuit under test then open up the circuit at the point where you wish to meas...

Page 14: ...tion switch to the green CAP position Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive jack Press the MODE button to indicate on...

Page 15: ...osition Insert the black lead banana plug into the negative COM jack Insert the red test lead banana plug into the positive jack Press the MODE button to indicate and on the display Touch the test pro...

Page 16: ...ices will indicate near 0V and an open device will indicate OL in both polarities 3 9 Capacitance Measurements To avoid electric shock disconnect power to the unit under test and discharge all capacit...

Page 17: ...t 30 seconds Read the temperature in the display Note The temperature probe is fitted with a K type mini connector A mini connector to banana connector adaptor is supplied for connection to the input...

Page 18: ...ll be damaged by insulation measurement voltage Many parts will be damaged undue 1000V and other ranges For example power factor capacitor low voltage insulation cable electronic dimmer and common ele...

Page 19: ...tor wire and all other components between the motor and the main switch If a weakness is indicated the motor and other components should be checked individually If the motor is disconnected at the mot...

Page 20: ...e best mode for most measurements For measurement situations requiring that a range be manually selected perform the following 1 Press the RANGE key The AUTO display indicator will turn off 2 Press th...

Page 21: ...lay MIN will display in right auxiliary display The meter will update the display each time a lower negative peak occurs Press the EXIT button to exit the PEAK HOLD mode Auto Power Off feature will be...

Page 22: ...t includes in sequence A upper limit buzzer alarm B lower limit buzzer alarm C auto power off time D turn off phonating E back lit time Use buttons to select the parameter 2 Press SET button continuou...

Page 23: ...O NOT use chemicals cleaning solvents or detergents USE ONLY FRESH BATTERIES OF THE RECOMMENDED SIZE AND TYPE Remove old or weak batteries so they do not leak and damage the unit IF THE METER IS TO BE...

Page 24: ...meter until the fuse cover is in place and fastened securely 5 Technical specifications Test voltage test current Measuring range Resolution Accuracy 50V 1 mA 50 k 0 01 5 M 0 0001 M 4 20 digits 5 50...

Page 25: ...gits 500 V 0 01 V 1 30 digits 1000 V 0 1 V 1 30 digits The specified accuracy for alternating voltage refers to 5 100 of the measuring range Direct current Measuring range Resolution Accuracy 500 A 0...

Page 26: ...digits 500 Hz 0 01 Hz 0 02 3 digits 5 kHz 0 0001 kHz 0 02 3 digits 50 kHz 0 001 kHz 0 02 3 digits 500 kHz 0 01 kHz 0 02 3 digits 5 MHz 0 0001 MHz 0 02 3 digits 50 MHz 0 001 MHz 0 02 3 digits 100 MHz...

Page 27: ...at 500V 1 5 at 1000V Display 50000 digit LCD illuminated with bargraph Automatic shutdown after 15 minutes Measurement rate update display 10 Hz Power supply 6 x 1 5V AA batteries Interface Wireless U...

Page 28: ...cally 3 1 1 5 1 1 0 or less Tested material status Considered as good insulation older types Not acceptable older types very high insulation resistance Modern type of good insulation system Fail Examp...

Page 29: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 30: ...dustrial needs com info pce italia it www pce instruments com deutsch www pce instruments com english www pce instruments com italiano The Netherlands Chile Hong Kong PCE Brookhuis B V PCE Instruments...

Reviews: