background image

 

 

 

©  PCE Instruments 

 

Specifications  

Functions

 

PE pre-test (protective earth) 

available, error 

PP simulation (charging cable coding) 

open, 13 A, 20 A, 32 A, 63 A 

CP simulation (communication line) 

A, B, C, D, error 

Outputs (for test purposes only)

 

Measurement connections 

L1, L2, L3, N, PE 
max. 250 / 430 V AC, 10 A  
laboratory plug 

Schuko connection 

max. 250 V AC, 10 A 

Fuse of the Schuko connection 

Fuse F 10 A / 250 V, 
5 x 20 mm 

CP signal output 

±12 V PWM 

Further specifications

 

Input voltage 

1-phase: 250 V AC / 3-phase 430 V AC, 
50 / 60 Hz, max. 10 A 

Charging cable plug type 1 

AC charging mode 3, compatible with 
IEC62196-1 type 1 or SAE J1772 with 
vehicle connector (type 1, 5-pin, 1-phase) 

Charging cable plug type 2 

AC charging mode 3, compatible with 
IEC62196-2 type 1 or SAE J1772 with 
vehicle connector (type 2, 7-pin, 3-phase) 

Measurement category 

CAT II 300 V 

Protection class 

IP54 

Degree of pollution 

Operating conditions 

0 ... 40 °C / 32 ... 104 °F, 10 ... 85 % RH, 
non-condensing 

Storage conditions 

-10 ... 50 °C / 14 ... 122 °F, 10 ... 85 % RH, 
non-condensing 

Maximum working height 

max. 2000 m / 6561 ft 

Dimensions (handheld only) 

277 x 109 x 63 mm / 10.9 x 4.3 x 2.4" 

Weight 

approx. 1 kg / 2.2 lb 

Delivery scope 

1 x electrical vehicle tester PCE-EVSE 300, 1 x charging cable plug type 1, 1 x charging cable 
plug type 2, 1 x transport bag, 1 x user manual 

Safety symbols  

Symbol 

Meaning 

 

Follow the instructions 

 

Risk of electric shock 

 

Double insulation 

 

Connection must be made to the protective earth conductor "PE

” 

 

Reference, please pay special attention 

 
 

 

Summary of Contents for PCE-EVSE 300

Page 1: ...rical Vehicle Tester User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last c...

Page 2: ...station 5 8 Operation of electrical vehicle tester 7 8 1 PE test 7 8 2 PP test signal 7 8 3 CP vehicle simulation 8 8 4 CP signal output protective earth 8 8 5 CP error test key E simulation 8 8 6 PE...

Page 3: ...opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp c...

Page 4: ...e 1 5 pin 1 phase Charging cable plug type 2 AC charging mode 3 compatible with IEC62196 2 type 1 or SAE J1772 with vehicle connector type 2 7 pin 3 phase Measurement category CAT II 300 V Protection...

Page 5: ...Description 1 Risk of electric shock if the signal lamp lights up during the PE test If this lamp lights up no further tests must be carried out until the PE error has been rectified 2 If the connecti...

Page 6: ...20 A 32 A 63 A 6 Schuko connection plug 7 Schuko laboratory plug connection 4 mm 8 Phase laboratory plug connection 4 mm L1 L2 L3 9 Signal lamp for phase connection 10 Neutral conductor laboratory plu...

Page 7: ...tester supports charging plugs of the types 1 and 2 To establish a connection first select the appropriate plug and connect it to the electrical vehicle tester You can then connect the charging plug...

Page 8: ...PCE Instruments 6 Direct connection to the charging station and connection via an adaptor with the permanently installed cable...

Page 9: ...is a risk of electric shock as there is an external voltage on the protective conductor No further work or tests should be carried out until this fault has been rectified Note Make sure that you do n...

Page 10: ...heck the output signal Pulse width modulation PWM is expected The signal should be designed according to IEC EN 62851 1 and IEC HD 60364 7 722 8 5 CP error test key E simulation The CP error test key...

Page 11: ...ive cleaning agents should be used Before cleaning all cables must be disconnected from the tester After cleaning the meter may be used as soon as it is completely dry 9 2 Transport and storage For tr...

Page 12: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 13: ...hazlar Ltd ti Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece...

Reviews: