background image

 

 

 

©  PCE Instruments 

 

Device description  

No. 

Description 

CP error test key "E" (simulation) 

PE error test key (simulation) 

PE test contact surface 

PE test signal lamp 

PP rotary selector switch (not connected, 13 A, 20 A, 32 A, 63 A) 

Schuko connection plug 

Schuko laboratory plug connection 4 mm 

Phase laboratory plug connection 4 mm (L1, L2, L3) 

Signal lamp for phase connection 

10 

Neutral conductor laboratory plug connection 4 mm 

11 

CP rotary selector switch A, B, C, D 

12 

Charging station connector (male) 

13 

Connection for charging station plug (female) 

14 

CP signal output 

15 

CP signal output connected to protective earth 

16 

Fuse  

 

Summary of Contents for PCE-EVSE 300

Page 1: ...rical Vehicle Tester User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last c...

Page 2: ...station 5 8 Operation of electrical vehicle tester 7 8 1 PE test 7 8 2 PP test signal 7 8 3 CP vehicle simulation 8 8 4 CP signal output protective earth 8 8 5 CP error test key E simulation 8 8 6 PE...

Page 3: ...opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp c...

Page 4: ...e 1 5 pin 1 phase Charging cable plug type 2 AC charging mode 3 compatible with IEC62196 2 type 1 or SAE J1772 with vehicle connector type 2 7 pin 3 phase Measurement category CAT II 300 V Protection...

Page 5: ...Description 1 Risk of electric shock if the signal lamp lights up during the PE test If this lamp lights up no further tests must be carried out until the PE error has been rectified 2 If the connecti...

Page 6: ...20 A 32 A 63 A 6 Schuko connection plug 7 Schuko laboratory plug connection 4 mm 8 Phase laboratory plug connection 4 mm L1 L2 L3 9 Signal lamp for phase connection 10 Neutral conductor laboratory plu...

Page 7: ...tester supports charging plugs of the types 1 and 2 To establish a connection first select the appropriate plug and connect it to the electrical vehicle tester You can then connect the charging plug...

Page 8: ...PCE Instruments 6 Direct connection to the charging station and connection via an adaptor with the permanently installed cable...

Page 9: ...is a risk of electric shock as there is an external voltage on the protective conductor No further work or tests should be carried out until this fault has been rectified Note Make sure that you do n...

Page 10: ...heck the output signal Pulse width modulation PWM is expected The signal should be designed according to IEC EN 62851 1 and IEC HD 60364 7 722 8 5 CP error test key E simulation The CP error test key...

Page 11: ...ive cleaning agents should be used Before cleaning all cables must be disconnected from the tester After cleaning the meter may be used as soon as it is completely dry 9 2 Transport and storage For tr...

Page 12: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Page 13: ...hazlar Ltd ti Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece...

Reviews: