Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The 
device  may  only  be  used  by  qualified  personnel  and  repaired  by  PCE  Instruments  personnel. 
Damage or injuries caused by non-observance of the manual are excluded from our liability and 
not covered by our warranty. 
 

 

The device must only be used as described in this instruction manual. If used otherwise, 
this can cause dangerous situations for the user and damage to the meter. 

 

The instrument may only be used if the environmental conditions (temperature, relative 
humidity, …) are within the ranges stated in the technical specifications. Do not expose 
the device to extreme temperatures, direct sunlight, extreme humidity or moisture. 

 

Do not expose the device to shocks or strong vibrations. 

 

The case should only be opened by qualified PCE Instruments personnel. 

 

Never use the instrument when your hands are wet. 

 

You must not make any technical changes to the device. 

 

The appliance should only be cleaned with a damp cloth. Use only pH-neutral cleaner, 
no abrasives or solvents. 

 

The device must only be used with accessories from PCE Instruments or equivalent. 

 

Before each use, inspect the case for visible damage. If any damage is visible, do not 
use the device. 

 

Do not use the instrument in explosive atmospheres. 

 

The measurement range as stated in the specifications must not be exceeded under 
any circumstances. 

 

Non-observance of the safety notes can cause damage to the device and injuries to 
the user. 

 
We do not assume liability for printing errors or any other mistakes in this manual. 
 
We expressly point to our general guarantee terms which can be found in our general terms of 
business. 
 
If you have any questions please contact PCE Instruments. The contact details can be found at 
the end of this manual. 
 
 
 

 

Summary of Contents for PCE-CT 25FN

Page 1: ...ing Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last ch...

Page 2: ...Technical specifications 2 2 2 Delivery scope 2 3 System description 3 3 1 Device 3 3 2 Display and function keys 4 4 Operation 5 4 1 Insert replace battery 5 4 2 Make a measurement 5 4 3 Zero calibra...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...ter 20 mm Material thickness of substrate 0 30 mm 0 05 mm Radius convex 5 mm Radius concave 25 mm Measuring frequency max 2 measurements per second Power supply 9 V block battery Operating conditions...

Page 5: ...PCE Instruments 3 3 System description 3 1 Device 1 Display 2 Keypad 1 Sensor with contact surface 2 Trigger 3 Battery compartment cover...

Page 6: ...omatic power off 5 Current unit of measurement 6 Measured value 7 Statistical value for 2 8 Automatic sensor selection Key functions Key Press and release Press and hold F1 Change m mm mils Deleting t...

Page 7: ...mended to perform a zero calibration regularly to increase the accuracy of the measurements Prepare an uncoated sample one each for ferromagnetic Fe and non ferromagnetic N metals or use the zero stan...

Page 8: ...tings Then check the measurement accuracy with the zero standards from the calibration set If necessary perform the zero calibration described in chapter 4 3 6 Contact If you have any questions sugges...

Page 9: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Reviews: