1  Introduction 

Thank you for purchasing a colour meter from PCE Instruments. 
The colour meter PCE-CSM 7 is an ideal measuring device for application in quality control and offers 
high accuracy. When using the colour meter, there are different colour spaces available (CIE L*a*b*C*h, 
L*a*b, XYZ, RGB, L*u*v, C*H). The colour meter PCE-CSM 7 also comes with two different measuring 
apertures (Ø4 mm and Ø8 mm) for different applications. After a measurement with the PCE-CSM 7, the 
reading can be used as a standard value. Other readings can be recorded as a sample and later be 
compared to the reference value. In addition to the individual colour space coordinates, the deviation 
between the readings is also dis played. On the internal memory of the colour meter, you can store up to 
100 reference values and up to 20,000 samples. The measured data can also be transferred to a PC via 
USB and analysed with the included PC software. 
 

2  Safety notes 

Please read this manual carefully and completely before you use the device for the first time. The device 
may only be used by qualified personnel and repaired by PCE Instruments personnel. There is no 
warranty of damages or injuries caused by non-observance of the manual. 
 

 

This colour meter is a precise measuring device. Please avoid strong changes in the 
environmental conditions. This includes flickering lights as well as changes of the air temperature 
or air humidity. 

 

The device may only be used in the approved temperature range. 

 

Make sure the device is standing right on the measuring spot. Do not move it while the measuring 
procedure is in progress. Avoid shocks. 

 

Do not expose the device to water. Only use it in areas which fulfil the permitted environmental 
conditions. 

 

Keep the device clean and prevent dust or other particles from entering the measuring aperture. 

 

To clean the device, use a damp cloth. Do not use solvent-containing materials for cleaning. 

 

The case should only be opened by qualified personnel of PCE Instruments. 

 

You must not make any technical changes to the device. 

 

The instrument should never be placed with the user interface facing an object (e. g. keyboard 
side on a table). 

 

Only use the battery which is included in the package (3.7 V, 0.5 A). 

 

If you do not need the device for a longer period of time, please reset the white calibration and 
store it in in the carrying case.

 

 
This user's handbook is published by PCE Instruments without any guarantee. 
 
We expressly point to our general guarantee terms which can be found in our general terms of business. 
 
If you have any questions please contact PCE Instruments. 
 

 

Summary of Contents for PCE-CSM 7

Page 1: ...ter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busines...

Page 2: ...ances 11 5 3 5 Delete recorded data 11 5 3 6 Averaging 12 5 3 7 Display mode 12 5 3 8 Date Time setting 12 5 3 9 Light source 13 5 3 10 Specular reflection 13 5 3 11 Language 13 6 Settings 13 6 1 Colo...

Page 3: ...n observance of the manual This colour meter is a precise measuring device Please avoid strong changes in the environmental conditions This includes flickering lights as well as changes of the air tem...

Page 4: ...D50 A Lamp life 5 years more than 1 6 million measurements Display TFT 2 8 16 9 Storage 100 reference values standards 20 000 samples Interface USB Power supply Rechargeable lithium ion battery 3 7 V...

Page 5: ...Manual 5 4 System description 4 1 Button description 4 2 Interfaces...

Page 6: ...eter to a PC The baud rate is 115 200 bps 4 3 Battery Installing the battery 1 Make sure that the colour meter is turned off 2 Open the cover of the battery compartment 3 Insert the battery into the a...

Page 7: ...unter clockwise by about 20 degrees and pull it off see picture below Install the measuring aperture To install the measuring aperture put it in the allocated space and turn it clockwise by about 20 d...

Page 8: ...you turn on the device you are directed to the Standard Measurement screen To take a measurement follow these steps 1 Press and hold the testing button A light cone will then appear to help you aim a...

Page 9: ...a standard measurement 3 Now you can see the results and the deviation to the standard in the following screen Note While the measurement is in progress time duration 1 second all buttons are inactive...

Page 10: ...st have to place the device on top of it and make sure that the calibration plate is located under the measuring aperture If the auto calibration was successful you automatically get to the main scree...

Page 11: ...ect the desired option by using the arrow keys and and press Enter If you activate a tolerance you get to an input display where you can set the desired threshold value To do so use the arrow keys and...

Page 12: ...s and to select the desired option and press Enter to confirm Note CIE L a b C H is set by default 5 3 8 Date Time setting To set the time and date of the colour meter press the Menu button select Tim...

Page 13: ...r Here you have different options Use the arrow keys and to navigate and confirm the selection by pressing Enter 6 1 Colour offset Here you can choose if the colour offset is displayed or not Select a...

Page 14: ...g the arrow keys and and press Enter to confirm 6 6 Contrast Here you can adjust the contrast of the display Use the arrow keys and to select an option and press Enter to confirm 6 7 Restore factory s...

Page 15: ...ibration After that perform a black calibration 2 Fill in the powder Fill the powder into the powder compartment of the measuring plate After that put the powder test box back together see 7 1 1 Make...

Page 16: ...u can determine the colorimetric parameters of liquids pastes and powders 7 2 1 Structure The PCE CSM UTC consists of a base plate 1 an alignment plate for the colour meter 2 a measuring chamber 3 wit...

Page 17: ...measuring hole of the measuring chamber 3 Make sure that the colour meter is in the right place and tightened properly before moving on 2 Fill the tank 4 with the medium to be measured and put it int...

Page 18: ...er Please make sure that these indications are aligned properly see picture below 4 Perform a measurement with the colour meter 5 Clean the measuring device before each use Do not use abrasive or corr...

Page 19: ...contact PCE Instruments 8 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 8 2...

Reviews: