Manual
17
5.1.9 Tracking an underground current circuit
ATTENTION:
-
The power circuit most not be charged.
-
Connect the transmitter as shown in the figure.
-
The end of the grounding cable of the transmitter must be grounded properly.
-
Select the automatic mode on the receiver.
-
Use the displayed signal strength to search and trace the current circuit.
-
The distance between the grounding cable and the searches circuit must be as big as possible. If
the distance is too small, the signals and the current circuit cannot be accurately located.
-
The search depth is highly dependent on the ground (floor, soil) conditions. Select appropriate
reception sensitivities to locate the circuit accurately.
-
If you move the receiver slowly along the searched current circuit, you will find that the display
often changes. The strongest signals indicate the exact place of the current circuit.
-
The bigger the distance between the supply signals (transmitter) and the receiver, the lower the
signal strength and weaker the search will be.