![PCE Instruments PCE-BS 300 Manual Download Page 5](http://html1.mh-extra.com/html/pce-instruments/pce-bs-300/pce-bs-300_manual_1516096005.webp)
3.
Place a given number of samples of an item on the pan (the Sample Size should be either 10 20 50 or 100
pieces). The weight of these samples will show on the display.
4.
Press the
[PCS]
key several times to put the scale in PCS mode.
5.
Select the sample size (the same as you chose above) by pressing the [PCS] key. (press it as many times as
necessary to put it in the correct sample size ,the sample size is the same as in step three =10 20 50or100.
6.
Press the [UNIT] key, the display will show “selected pcs”, then the scale will remember the sample size you
selected and show the starting sample size on the display
(you can now remove the samples if you want to return the scale to 0)
7.
Place the items that you want counted onto the tray and the total number of items will show on the display.
8.
Presses the “PCS” key to exit the counting function and return to normal weighing or you can press ON/OFF
to turn the scale off to exit .
NOTE: the weight of unit sample > 10e.
4. WEIGHING
Before weighing
Whenever possible, please allow the balance to warm up for 10 minutes after first turning to power on, so that
the balance will function. Properly and accurately.
Error messages
EEEE: Overload
: Low battery
Calibration may be required before weighing.
Read "CALIBRATION" first and if necessary, calibrate your scale/balance for accurate weighing.
Weighing procedures
1. Press [ON/OFF] to turn on the scale/balance.
When power is turned on, all display segments appear on LCD for a few seconds and finally "0" will appear on
the display.
2. Select the weighing unit with [UNIT].
Press
[UNIT]
to select a weighing unit, eg. "g" " ct " " oz " " dwt " "ozt" "gn" "lb" "n". Once the unit has
been selected, the selected unit will be displayed to the weight value.
3. Start
weighing
Æ
If you do not use a container for weighing,
Verify the reading is "0". If not, press
[ZERO]
to display "0". Place objects on the weighing platform to weigh.
When the reading becomes stable, the stable indicator is displayed.
Æ
If you use a container for weighing,
Place an empty container on the platform.
Wait for the stability indicator to be displayed and press
[ZERO]
.
Place the objects to be weighed in the container.
When the reading becomes stable, the stable indicator is displayed.
Summary of Contents for PCE-BS 300