background image

Manual

Temperature

 Meter PCE - 777N

Version 1.0

Date of creation: 31.03.2016

Date of last change: 01.04.2016

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

[email protected]

Summary of Contents for PCE - 777N

Page 1: ...upiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busi...

Page 2: ...rocess 6 5 2 Switching device on and off 6 5 3 Measuring values frozen Data Hold 6 5 4 Selection of the temperature unit C F 6 5 5 MAX MIN function 6 5 6 Laser pointer and display backlighting 6 5 7 G...

Page 3: ...g may be switched on or off It enables temperature readings to be taken remotely quickly and easily from a safe distance Thus allowing the user to measure very high temperatures moving objects or surf...

Page 4: ...sed in an explosive atmosphere Before each use please check the device by measuring a known factor The measured value limits as stated in the specification table must not be exceeded The laser beam is...

Page 5: ...lue display 6 Key for laser and display backlighting 7 Measurement trigger 8 Battery compartment 1 Symbol for ongoing measuring process 2 Symbol for frozen measuring results Data Hold 3 Symbol for act...

Page 6: ...ng the trigger 7 the measuring device automatically keeps the measuring value on the display for approx 8 seconds No additional user tasks are necessary 5 4 Selection of the temperature unit C F To ch...

Page 7: ...sured surface Measurement of metallic surfaces It is recommended not to measure the temperature of shiny and polished metallic surfaces stainless steel and aluminium as the thermal emissions may fluct...

Page 8: ...pears on the display Replace the 9 V battery to prevent incorrect measurements and any resulting dangers Remove the battery compartment cover to replace the battery and take the old battery out and in...

Page 9: ...use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 9 Contact If you have any questions about our rang...