Manual 

 

System description 

(1)  Infrared sensor 

 

(2)  Laser pointer 

 

(3)  Display 

 

(4)  Key for unit °C (Centigrade) / °F (Fahrenheit) 

 

(5)  Selection key minimal / maximal value display 

 

(6)  Key for laser and display backlighting 

 

(7)  Measurement trigger  

 

(8)  Battery compartment 

 
 
 
 
 
 
 

 
 
 
 
 

 

 
 
 

(1)  Symbol for ongoing measuring 

process 

(2) 

Symbol for “frozen” measuring results 
(Data-Hold) 

(3)  Symbol for active laser point 
(4)  Emissivity (non-adjustable) 
(5)  Symbol for unit °C/°F 
(6)  Symbol for low battery level 
(7)  MAX/MIN value 
(8)  MAX/MIN symbol 
(9)  Measuring results 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for PCE - 777N

Page 1: ...upiter FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Busi...

Page 2: ...rocess 6 5 2 Switching device on and off 6 5 3 Measuring values frozen Data Hold 6 5 4 Selection of the temperature unit C F 6 5 5 MAX MIN function 6 5 6 Laser pointer and display backlighting 6 5 7 G...

Page 3: ...g may be switched on or off It enables temperature readings to be taken remotely quickly and easily from a safe distance Thus allowing the user to measure very high temperatures moving objects or surf...

Page 4: ...sed in an explosive atmosphere Before each use please check the device by measuring a known factor The measured value limits as stated in the specification table must not be exceeded The laser beam is...

Page 5: ...lue display 6 Key for laser and display backlighting 7 Measurement trigger 8 Battery compartment 1 Symbol for ongoing measuring process 2 Symbol for frozen measuring results Data Hold 3 Symbol for act...

Page 6: ...ng the trigger 7 the measuring device automatically keeps the measuring value on the display for approx 8 seconds No additional user tasks are necessary 5 4 Selection of the temperature unit C F To ch...

Page 7: ...sured surface Measurement of metallic surfaces It is recommended not to measure the temperature of shiny and polished metallic surfaces stainless steel and aluminium as the thermal emissions may fluct...

Page 8: ...pears on the display Replace the 9 V battery to prevent incorrect measurements and any resulting dangers Remove the battery compartment cover to replace the battery and take the old battery out and in...

Page 9: ...use them or give them to a recycling company which disposes of the devices in line with law If you have any questions please contact PCE Instruments 9 Contact If you have any questions about our rang...

Reviews: