background image

Manual 

 

13 

 

7  Software 

 
First, please install the software and the USB driver “CP2102 USB to UART Bridge Controller” from the 
CD-ROM. If there are problems with the installation, you can find the driver installer 
“CP210xVCPInstaller.exe” in the folder “driver” on the CD. 
 

  

 

 

You can operate the anemometer via the PC software 

 

 

Data recording starts automatically 
 

 

You still have to adjust settings like the cross-sectional area on the device itself 
 

 

You can select the parameters to be measured by using check fields 
 

 

You can export, save and print the measured data 

Summary of Contents for PCE-423

Page 1: ...er FL 33458 USA From outside US 1 Tel 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business...

Page 2: ...ions 9 5 2 1 Averaging over a certain amount of readings 9 5 2 2 Averaging over a certain period of time 9 5 2 3 Hold function 9 5 2 4 MIN MAX function 9 5 3 Exchange the battery 10 6 Setup 10 6 1 Set...

Page 3: ...PC or laptop to transfer data continuously Data can be stored in either txt or csv format for further analysis 2 Safety notes Please read this manual carefully and completely before you use the device...

Page 4: ...digit of measured value Temperature 1 C General specifications Thermal probe Telescopic probe Length 185 1000 mm Max diameter 12 mm Min diameter 10 mm Interface USB Display LCD display 46 7 x 60 mm P...

Page 5: ...hows flow rate air velocity temperature or cross sectional area 6 Indication for recording REC or maximum minimum value MAX MIN 7 Icon for averaging over a certain amount of readings 8 Mean value icon...

Page 6: ...ess and hold for 2 seconds to go back to normal mode Press to change between flow rate and temperature indication on the secondary display 5 Operation 5 1 To carry out a measurement 1 Connect the sens...

Page 7: ...into the telescopic tube when extending it to prevent damage to the cable 6 On top of the sensor you can find arrows which indicate the flow direction Please make sure that these arrows are in line wi...

Page 8: ...Manual 8 Flow rate sensor flow direction...

Page 9: ...appears on the secondary display To change the measuring unit press After doing so you can start averaging by pressing The time indication in the main display starts to run You can also pause and resu...

Page 10: ...ave the following options UNIT Here you can choose the unit of the cross sectional area You can switch between in m and ft AREA Here you can adjust the cross sectional area SLP Here you can activate d...

Page 11: ...Manual 11...

Page 12: ...rts to flash You can now set its value from 0 to 9 by using and Again press to confirm The next digit starts to flash and you can set its value as described above Repeat this procedure until you have...

Page 13: ...u can find the driver installer CP210xVCPInstaller exe in the folder driver on the CD You can operate the anemometer via the PC software Data recording starts automatically You still have to adjust se...

Page 14: ...contact PCE Instruments 8 1 PCE Instruments UK By post PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southampton Hampshire United Kingdom SO31 4RF By phone 02380 987 035 8 2...