PCE Instruments BSH series User Manual Download Page 13

 

 

©  PCE Instruments 

11 

 

Eng

li

s

h

 

PCE Instruments contact information 

 

Germany 

France 

Spain 

PCE Deutschland GmbH 

PCE Instruments France EURL 

PCE Ibérica S.L. 

Im Langel 4 

76, Rue de la Plaine des Bouchers 

Calle Mayor, 53 

D-59872 Meschede 

67100 Strasbourg 

02500 Tobarra (Albacete) 

Deutschland  

France  

España 

Tel.: +49 (0) 2903 976 99 0 

Téléphone: +33 (0) 972 3537 17  

Tel. : +34 967 543 548 

Fax: +49 (0) 2903 976 99 29 

Numéro de fax: +33 (0) 972 3537 18 

Fax: +34 967 543 542 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/deutsch 

www.pce-instruments.com/french 

www.pce-instruments.com/espanol 

 
 

 

 

United States of America 

United Kingdom 

Italy 

PCE Americas Inc. 

PCE Instruments UK Ltd 

PCE Italia s.r.l. 

711 Commerce Way suite 8 

Units 12/13 Southpoint Business Park 

Via Pesciatina 878 / B-Interno 6 

Jupiter / Palm Beach 

Ensign Way, Southampton 

55010 LOC. GRAGNANO  

33458 FL  

Hampshire  

CAPANNORI (LUCCA) 

USA 

United Kingdom, SO31 4RF 

Italia 

Tel: +1 (561) 320-9162 

Tel: +44 (0) 2380 98703 0 

Telefono: +39 0583 975 114  

Fax: +1 (561) 320-9176 

Fax: +44 (0) 2380 98703 9 

Fax: +39 0583 974 824  

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/us 

www.pce-instruments.com/english 

www.pce-instruments.com/italiano 

 
 

 

 

The Netherlands 

Chile 

Hong Kong 

PCE Brookhuis B.V. 

PCE Instruments Chile SPA 

PCE Instruments HK Ltd. 

Institutenweg 15 

RUT 76.423.459-6 

Unit J, 21/F., COS Centre 

7521 PH Enschede 

Badajoz 100 oficina 1010 Las Condes 

56 Tsun Yip Street 

Nederland 

Santiago de Chile / Chile 

Kwun Tong 

Telefoon: +31 (0) 900 1200 003 

Tel. : +56 2 24053238 

Kowloon, Hong Kong 

Fax: +31 53 430 36 46 

Fax: +56 2 2873 3777 

Tel: +852-301-84912 

[email protected] 

[email protected] 

[email protected] 

www.pce-instruments.com/dutch 

www.pce-instruments.com/chile 

www.pce-instruments.cn 

 
 

 

 

China 

Turkey 

Pingce (Shenzhen) Technology Ltd. 

PCE Teknik Cihazları Ltd.Şti. 

West 5H1,5th Floor,1st Building 

Halkalı Merkez Mah. 

Shenhua Industrial Park, 

Pehlivan Sok. No.6/C 

Meihua Road,Futian District 

34303 Küçükçekmece - 

İstanbul 

Shenzhen City 

Türkiye 

China  

Tel: 0212 471 11 47 

Tel: +86 0755-32978297 

Faks: 0212 705 53 93 

[email protected] 

[email protected] 

www.pce-instruments.cn 

www.pce-instruments.com/turkish 

 
 

Summary of Contents for BSH series

Page 1: ...p scale PCE BSH series User Manual User manuals in various languages Deutsch fran ais italiano espa ol portugu s nederlands t rk polski can be downloaded here www pce instruments com Last change 28 Oc...

Page 2: ...2 2 1 Technical specifications 2 2 2 Delivery contents 2 3 System description 3 4 Getting started 4 5 Operation 4 5 1 Measurement 4 5 2 Further functions 5 5 3 Settings 6 6 Calibration 9 6 1 When to...

Page 3: ...evice to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to t...

Page 4: ...klight 20 mm character height Platform 160 x 180 mm Data interface USB Taring Multiple taring over full range Operating temperature 0 40 C Power supply 6 x 1 5 V AA batteries Mains adaptor 12 V 500 mA...

Page 5: ...Display ON OFF key Turn the scales ON OFF ZERO key Zero the display PRINT key Print the current reading UNIT key PCS key Switch the measuring unit g ct oz tola Piece counting function Bottom side Powe...

Page 6: ...properly Mains adaptor Connect the mains adaptor to the scales Mains adaptor connection 5 Operation 5 1 Measurement Press the ON OFF key to turn on the scales After turning on the scales it performs...

Page 7: ...t 5 2 Further functions 5 2 1 Piece counting function Turn on the scales and wait for the display to show 0 Press the ZERO key to zero the display if necessary Now press the PCS key The display shows...

Page 8: ...ress the ZERO key to go to the next setting where you can set the parity You can choose between P NONE P EVEN and P Odd Use the UNIT key to switch between these options By pressing the ZERO key you ge...

Page 9: ...Conversion Resolution 10 kg G 1 kg 1 000 g 0 2 g Oz 1 kg 35 28 oz 0 1 oz Lb 1 kg 2 2045 lb 0 0005 lb Dwt 1 kg 643 0 dWt 0 2 dWt Ozt 1 kg 32 15 ozt 0 01 ozt Ct 1 kg 5000 ct 1 ct tl T 1 kg 26 670 tl T...

Page 10: ...2 3 4 5 8 10 20 FS Zero range YZr 10 FS 3 4 5 10 FS Taring range Ytr 100 FS 100 50 FS Overload indication Our 0 FS 2 5 10 0 FS Key sounds bZ ON ON OFF Activate taring function Zt ON ON OFF Auto power...

Page 11: ...scales The scales now perform the self test procedure Once the display shows press the ZERO key The display now shows CAL Press the ZERO key again to confirm The display now shows the recommended cal...

Page 12: ...ained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our...

Page 13: ...975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce instruments com english www p...

Page 14: ...PCE Instruments...

Page 15: ...PCE Instruments...

Page 16: ...ts User manuals in various languages German French Italian Spanish Portuguese Dutch Turkish Polish Russian Chinese can be downloaded here www pce instruments com Specifications are subject to change w...

Reviews: