Manual
12
5.4
Entering of the dimensions
To achieve probable measurement results, you need to enter the distances between the sensors, the
coupling and the machine bases first. The following figures show the required dimensions for both,
horizontally and vertically mounted machines.
Horizontal alignment
1
Stationary machine
2
Sensor S
3
Sensor M
4
Moveable machine
F1
Front machine base
F2
Rear machine base
S-M
distance between the measurement sensors
S-C
distance between sensor S and the middle of the coupling
S-F1
distance between sensor S and the machine base F1
S-F2
distance between sensor S and the machine base F2 (needs to be larger than S-F1). If
the machine has three pairs of machine bases, the value can be adjusted after the
measurement. After a new measurement, you receive the corrective values for the third
pair of machine base.