Manual
5
3
Specifications
There are different kinds of methods for measurement of hardness:
Brinell, Rockwell, Vickers, Leeb, etc. are usually used.
Rockwell and Brinell tests force with larger test loads and large stamps what often leads to visible
damage to the material surface. The hardness-measuring of heavy work pieces, built-in machinery and
permanently assembled parts is therefore relatively difficult.
The ultrasonic hardness tester PCE-5000 uses the Ultrasonic Contact Impedance procedure to carry out
comparative hardness measurements for test pieces, with the advantages of a highly accurate, efficient,
portable and non-destructive measurement with simple operation.
3.1
Technical Specifications
Measurement range
Rockwell
20,3 … 68,0 HRC
41,0 … 100,0 HRB
61,0 … 85,6 HRA
Brinell
85 … 650 HB
Vickers
50 … 999 HV
Tensile strength
255 … 2180 N/mm²
Accuracy
Rockwell HRD
±1,5 HR
Brinell HB
±3 %
Vickers HV
±3 %
General technical data
Measurement principle
Ultrasonic Contact Impedance
Direction of measurement
360 °
Measurement time
2 seconds
HRC, HV, HB, additionally: HRA, HRB, MPa
Display
LCD with backlight
Minimum material thickness
2 mm
Storage
Up to 2000 measurement groups
up to 20 calibration sets
Measurement probe
20 N (standard)
Cable length
1,5 m
Functions
Single value, Min. / Max., average value
Power supply
4,2 V battery, 4800 mAh
Operation time
Approx. 10 hours (without backlight)
Automatic shutdown
After 30 minutes of inactivity
Operation conditions
Temperature: -
10 … +40°C
Humidity:
≤ 85 % r.h.
Storage conditions
Temperature: -
20 … +60°C
Humidity:
≤ 85 % r.h.
Dimensions
162 x 81 x 31 mm
Weight
Approx. 755 (incl. probe)