background image

 

©  PCE Instruments 

 

 
 
 
 
 

 

 

PCE-GM 55 Gloss Meter 

User Manual 

User manuals in various languages (français, 

italiano, español, português, nederlands, türk, polski, 

русский, 

中文

) can be found by using our 

product search on: www.pce-instruments.com 

Last change: 21 October 2019 

v1.0 

E

nglis

h

 

Summary of Contents for GM 55

Page 1: ...Gloss Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 21...

Page 2: ...evice description 3 5 Display description 4 6 On off 5 7 Automatic Power Off 5 8 Measurement 5 9 Calibration 5 10 New calibration standard 5 11 Saving viewing deleting measured data 6 12 Recharging th...

Page 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Page 4: ...20 45 75 Measuring range 0 200 gloss units Resolution 0 1 gloss units Accuracy 1 gloss units on reference standard Repeatability 0 5 gloss units 0 99 9 GE Measuring surface 7 x 14 mm elliptical Data...

Page 5: ...to set measuring angle ANGLE 4 CAL key for calibration and to decrease parameters 5 MEAS key to make a measurement 6 DEL key to delete reading 7 RD key to view memory and increase parameter 8 USB inte...

Page 6: ...tion 1 Indicates that you are in calibration mode 2 Reading 3 Measuring mode 4 Measuring angle 5 Continuous mode 6 Memory readout mode 7 Memory item no 8 Indicates that battery must be recharged 9 Ind...

Page 7: ...ed continuously To switch between these measuring functions press and hold the on off key until SC is displayed after OFF was shown To change the measuring angle press the ANGLE key 9 Calibration The...

Page 8: ...ode Note If you try to enter memory readout mode when no measuring data are available the display will show Err1 Memory readout mode can only be opened if data have been saved 12 Recharging the batter...

Page 9: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Page 10: ...583 975 114 Fax 49 0 2903 976 99 9971 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce instruments com info pce instruments co uk info pce italia it www pce instruments com deutsch www pce instrumen...

Reviews: