background image

Model Number

260A 03

3-COMPONENT ICP® FORCE SENSOR

Revision: R
ECN #: 50553

P erfo rm an ce

EN G L ISH

SI

Sensitivity(± 20 %)(Z Axis)

0.25 mV/lb

0.06 mV/N

[1][2]

Sensitivity

(± 20 %)(X or Y Axis)

1.25 mV/lb

0.28 mV/N

[1][2]

Measurement Range(Z Axis)

10,000 lb

44.48 kN

Measurement Range

(X or Y Axis)

4,000 lb

17.79 kN

Maximum Force(z axis)

11,000 lb

48.93 kN

Maximum Force

(x or y axis)

4,400 lb

19.57 kN

Maximum Moment(z axis)

240 ft-lb

325.4 Nm

Maximum Moment

(x or y axis)

325 ft-lb

440.7 Nm

Broadband Resolution(z axis)

0.05 lb-rms

0.222 N-rms

[3]

Broadband Resolution

(x or y axis)

0.01 lb-rms

0.04 N-rms

[3]

Upper Frequency Limit

39,000 Hz

39,000 Hz

Low Frequency Response(- 5 %)(z-axis)

0.01 Hz

0.01 Hz

Low Frequency Response

(- 5 %)(x or y axis)

0.001 Hz

0.001 Hz

Non-Linearity

≤ 1 % FS

≤ 1 % FS

[4]

Cross Talk(between x and y axis)

± 3 %

± 3 %

Cross Talk

(between (x or y axis) and z axis)

± 5 %

± 5 %

En viro n m en tal

Temperature Range

-65 to +250 °F

-54 to +121 °C

Electrical

Full Scale Output(Z Direction)

± 2.5 VDC

± 2.5 VDC

Full Scale Output

(X and Y Direction)

± 5 VDC

± 5 VDC

Discharge Time Constant(z axis)

≥ 50 sec

≥ 50 sec

Discharge Time Constant

(x or y axis)

≥ 500 sec

≥ 500 sec

Excitation Voltage(all channels)

20 to 30 VDC

20 to 30 VDC

Constant Current Excitation(all channels)

2 to 20 mA

2 to 20 mA

Output Impedance

≤ 100 Ohm

≤ 100 Ohm

Output Bias Voltage

8 to 14 VDC

8 to 14 VDC

Spectral Noise(1 Hz)(X & Y)

0.003 lb/√Hz

0.0134 N/√Hz

Spectral Noise

(10 Hz)(X & Y)

0.001 lb/√Hz

0.00445 N/√Hz

Spectral Noise

(100 Hz)(X & Y)

0.0004 lb/√Hz

0.00178 N/√Hz

Spectral Noise

(1,000 Hz)(X & Y)

0.0001 lb/√Hz

0.000445 N/√Hz

Spectral Noise

(1 Hz)(Z)

0.02 lb/√Hz

0.089 N/√Hz

Spectral Noise

(10 Hz)(Z)

0.005 lb/√Hz

0.0222 N/√Hz

Spectral Noise

(100 Hz)(Z)

0.002 lb/√Hz

0.0089 N/√Hz

Spectral Noise

(1,000 Hz)(Z)

0.0005 lb/√Hz

0.00222 N/√Hz

Output Polarity

Positive

Positive

P h ysical

Preload

40,000 lb

178 kN

[5]

Stiffness(z axis)

38.8 lb/µin

6.8 kN/µm

[3]

Stiffness

(x or y axis)

11.4 lb/µin

2.0 kN/µm

[3]

Size (Height x Length x Width x Bolt Diameter x ID x
Sensing Surface)

0.790 in x 2.25 in x 2.25 in x 1 in x

1.023 in x 1.800 in

20.07 mm x 57.1 mm x 57.1 mm x 25

mm x 25.98 mm x 45.72 mm

Weight

9.56 oz

271 gm

Housing Material

Stainless Steel

Stainless Steel

Sealing

Hermetic

Hermetic

Electrical Connector

4-Pin

4-Pin

Electrical Connection Position

Side

Side

[6]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Piezotronics, Inc.

W

 - Water Resistant Cable

Electrical Connection Position

Side

Side

OP TION A L  VERSION S

Optional versions have identical specifications and accessories as listed for the standard model except

where noted below. More than one option may be used.

N OTES:

[1]Sensitivites are for listed preload. Sensitivites may vary ±5% depending on preload used.
[2]Sensitivities are dependent upon supplied bolt.
[3]Typical.
[4]Zero-based, least-squares, straight line method.
[5]Preload should be at least 10 times the X and Y operating range used.
[6]See PCB Declaration of Conformance PS023 for details.

Date: 04/17/2020

Date: 04/17/2020

Date: 04/17/2020

Date: 04/17/2020

7754

Entered: LK

Engineer: RPF

Sales: KK

Approved: RPF

Spec Number:

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]

SU P P L IED A C C ESSORIES:

Model 081A71 Mounting Stud (1)
Model 082B06 Anti-Friction Washer (1)
Model 083A11 Pilot Bushing (1)
Model M081A71 Mounting Stud (1)

Summary of Contents for M260A03

Page 1: ...rce Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...tallation outline drawing and specification sheet at the back of this manual for details and dimensions of the particular sensor model number s purchased The following pages give a brief description o...

Page 7: ...ring mounting and preload requirements Figure 4 outlines some possible mounting configurations to which the ring series may be installed Figure 4 Series 201 to 207 ICP Ring Force Sensor Possible Inst...

Page 8: ...simultaneously measuring force in three 3 orthogonal directions X Y and Z Internally three sets of quartz crystals are cut oriented and preloaded so the maximum output from the crystal cut for the spe...

Page 9: ...eturning the sensor to PCB for recalibration Figure 8 SERIES 3 COMPONENT TRIAX FORCE SENSORS PENETRATION Penetration style sensors are similar to the axial models but are specifically designed for com...

Page 10: ...t facing or surface grinding Surface flatness should be held to within 0 001 TIR over the entire mating surface When mounting sensors between two plates care should be taken to assure mounting surface...

Page 11: ...he left in Figure 13 part of the force between the two structures is shunted through the mounting stud The amount of force shunted is dependent on the stud material but may be up to 5 of the total for...

Page 12: ...ce the installer can monitor the sensor output voltage directly for correct preloading Monitor the output from the Z axis connector when preloading 3 component type sensors These sensors require a pre...

Page 13: ...eters depending on the frequency of interest It is necessary to supply the sensor with a 2 to 20 mA constant current at 20 to 30 VDC through a current regulating diode or equivalent circuit contained...

Page 14: ...ant in the system For this reason the readout device as well as the signal conditioner must be DC coupled Figure 16 Characteristic Discharge Time Constant Curve The discharge time constant represents...

Page 15: ...urned to the factory for servicing in the event of serious malfunction Observe the following precautions in using the sensor A Do not exceed the maximum load levels for the force sensor see specificat...

Page 16: ...Spectral Noise 100 Hz Z 0 002 lb Hz 0 0089 N Hz Spectral Noise 1 000 Hz Z 0 0005 lb Hz 0 00222 N Hz OutputPolarity Positive Positive Physical Preload 40 000 lb 178 kN 5 Stiffness z axis 38 8 lb in 6...

Page 17: ......

Page 18: ......

Page 19: ......

Reviews: