background image

Model Number

209C11

ICP® FORCE SENSOR

Revision: F
ECN #: 45224

Performance

ENGLISH

SI 

Sensitivity(± 15 %)

2200 mV/lb

494,604 mV/kN

Measurement Range(Compression)

2.2 lb

0.00979 kN

Measurement Range(Tension)

1.0 lb

0.00445 kN

Maximum Static Force(Compression)

11 lb

0.0489 kN

Maximum Static Force(Tension)

1.0 lb

0.00445 kN

Broadband Resolution(1 to 10,000 Hz)

0.00002 lb-rms

0.00009 N-rms

[1]

Low Frequency Response(-5 %)

0.5 Hz

0.5 Hz

[2]

Upper Frequency Limit

30,000 Hz

30,000 Hz

[3]

Environmental

Temperature Range

-65 to +250 °F

-54 to +121 °C

Temperature Coefficient of Sensitivity

 0.05 %/°F

 0.09 %/°C

Electrical

Discharge Time Constant(at room temp)

 1 sec

 1 sec

Excitation Voltage

18 to 30 VDC

18 to 30 VDC

Constant Current Excitation

2 to 20 mA

2 to 20 mA

Output Impedance

 100 Ohm

 100 Ohm

Output Bias Voltage

8 to 12 VDC

8 to 12 VDC

Spectral Noise(1 Hz)

0.0000044 lb/

Hz

0.0000197 N/

Hz

[1]

Spectral Noise(10 Hz)

0.0000005 lb/

Hz

0.0000021 N

Hz

[1]

Spectral Noise(100 Hz)

0.0000001 lb/

Hz

0.0000006 N/

Hz

[1]

Spectral Noise(1000 Hz)

0.0000000 lb/

Hz

0.0000002 N/

Hz

[1]

Output Polarity(Compression)

Positive

Positive

Physical

Stiffness

2 lb/µin

0.35 kN/µm

[1]

Size (Hex x Height)

0.375 in x 0.83 in

9.53 mm x 21.08 mm

Weight

0.29 oz

8.2 gm

Housing Material

Stainless Steel

Stainless Steel

Sealing

Hermetic

Hermetic

Electrical Connector

10-32 Coaxial Jack

10-32 Coaxial Jack

Electrical Connection Position

Side

Side

Mounting Thread

10-32 Female

No Metric Equivalent

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Group, Inc. 

M

- Metric Mount

Supplied Accessory : Model M081A05 Mounting Stud 10-32 to M6 x 0.75 x 0.27" long BeCu 

(H900), no shoulder (1)

N

- Negative Output Polarity

Output Polarity(Compression)

Negative

Negative

W

- Water Resistant Cable

Electrical Connector

Sealed Cable

Sealed Cable

Electrical Connection Position

Side

Side

NOTES:

[1]Typical.
[2]Calculated from discharge time constant.

[3]Estimated using rigid body dynamics calculations.
[4]See PCB Declaration of Conformance PS023 for details.

SUPPLIED ACCESSORIES: 

Model 081A05 Mounting stud, 10-32 to 10-32 x 0.27" long, BeCu (H900), no shoulder (1)
Model 084A38 Thermal boot (for Series 209) (1)

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]

[4]

OPTIONAL VERSIONS

Optional versions have identical specifications and accessories as listed for the standard model 

except where noted below. More than one option may be used.

Entered: LK

Engineer: MJK

Sales: KWW

Approved: APB

Spec Number:

Date: 3/29/2016

Date: 3/29/2016

Date: 3/29/2016

Date: 3/29/2016

8891 

Summary of Contents for M209C11

Page 1: ...2 2 lb comp 1 lb tension 2200 Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fa...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...tallation outline drawing and specification sheet at the back of this manual for details and dimensions of the particular sensor model number s purchased The following pages give a brief description o...

Page 7: ...ring mounting and preload requirements Figure 4 outlines some possible mounting configurations to which the ring series may be installed Figure 4 Series 201 to 207 ICP Ring Force Sensor Possible Inst...

Page 8: ...simultaneously measuring force in three 3 orthogonal directions X Y and Z Internally three sets of quartz crystals are cut oriented and preloaded so the maximum output from the crystal cut for the spe...

Page 9: ...eturning the sensor to PCB for recalibration Figure 8 SERIES 3 COMPONENT TRIAX FORCE SENSORS PENETRATION Penetration style sensors are similar to the axial models but are specifically designed for com...

Page 10: ...t facing or surface grinding Surface flatness should be held to within 0 001 TIR over the entire mating surface When mounting sensors between two plates care should be taken to assure mounting surface...

Page 11: ...he left in Figure 13 part of the force between the two structures is shunted through the mounting stud The amount of force shunted is dependent on the stud material but may be up to 5 of the total for...

Page 12: ...ce the installer can monitor the sensor output voltage directly for correct preloading Monitor the output from the Z axis connector when preloading 3 component type sensors These sensors require a pre...

Page 13: ...eters depending on the frequency of interest It is necessary to supply the sensor with a 2 to 20 mA constant current at 20 to 30 VDC through a current regulating diode or equivalent circuit contained...

Page 14: ...ant in the system For this reason the readout device as well as the signal conditioner must be DC coupled Figure 16 Characteristic Discharge Time Constant Curve The discharge time constant represents...

Page 15: ...urned to the factory for servicing in the event of serious malfunction Observe the following precautions in using the sensor A Do not exceed the maximum load levels for the force sensor see specificat...

Page 16: ...Stainless Steel Sealing Hermetic Hermetic Electrical Connector 10 32 Coaxial Jack 10 32 Coaxial Jack Electrical Connection Position Side Side Mounting Thread 10 32 Female No Metric Equivalent All spe...

Page 17: ......

Reviews: