background image

1

1

2

2

3

3

4

4

A

A

B

B

CODE

IDENT. NO.

52681

DWG. NO.

SCALE:

SHEET

DRAWN

CHECKED

ENGINEER

TITLE

UNLESS OTHERWISE SPECIFIED TOLERANCES ARE:

DIMENSIONS IN MILLIMETERS

[ IN BRACKETS ]

XX

    

±

 

0.13

ANGLES

  

 

2 DEGREES

3425 WALDEN AVE. DEPEW, NY 14043

(716)  684-0001 E-MAIL:  [email protected]

DIMENSIONS  IN INCHES

DECIMALS     XX

  

 

±.01

ANGLES

  

 

2 DEGREES

FILLETS AND RADII 

 .003 - .005 

DECIMALS     X

   

 ±

 

0.3

FILLETS AND RADII 

0.07 - 0.13 

INSTALLATION DRAWING

18551

1 OF 1

FULL

MODEL 607 SERIES

 

XXX   ±.005

JDM

10/9/14

ECB

10/9/14

DRK

10/9/14

18

55

1

PCB Piezotronics Inc. claims proprietary rights in

the information disclosed hereon.  Neither it nor any

reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.

REVISIONS

REV

DESCRIPTION

DIN

B

ADDED METRIC MOUNTING INFORMATION

43341

FIG 1: A 1/8" HEX ALLEN

KEY IS REQUIRED FOR THE ENGLISH

MOUNTING STUD.  A 3MM HEX 

ALLEN KEY IS REQUIRED FOR THE 

METRIC MOUNTING STUD. APPLY

SILICONE GREASE TO ALL MOUNTING

SURFACES (SEE ARROWS FIG 1 & 2)

 

FIG 2: TIGHTEN THE 

MOUNTING STUD USING

THE ALLEN KEY.  TORQUE

THE MOUNTING STUD TO 

WITHIN 3 TO 4 FT-LBS.

(4.1 TO 5.4 Nm)

 

FIG 3: THREAD THE SENSOR'S 

HEX NUT ONTO THE MOUNTING 

STUD. POSITION THE CABLE OR

CONNECTOR TO THE DESIRED

LOCATION AND HAND TIGHTEN 

THE HEX NUT.

FIG 4: TIGHTEN THE HEX 

NUT USING A TORQUE WRENCH

TO WITHIN 2 TO 3 FT-LBS 

(2.7 TO 4.1 Nm) WHILE HOLDING 

THE CABLE OR CONNECTOR

IN THE DESIRED LOCATION.

 

FIG 5: IF FOR ANY REASON THE MOUNTING

STUD DOES NOT 

DISENGAGE FROM THE SENSOR, USE A

FLAT HEAD SCREW DRIVER 

TO HOLD THE STUD WHILE TURNING THE

HEX NUT COUNTERCLOCKWISE

WITH A WRENCH.

 

SILICONE GREASE

SILICONE GREASE

2

METRIC MOUNTING HOLE PREPARATION:
DRILL Ø.199[Ø5.05] 

.300[7.62] MIN

TAP M6 X 1-6g 

.200[5.08] MIN

 
ENGLISH MOUNTING HOLE PREPARATION:
DRILL Ø.218[Ø5.54] 

.300[7.62] MIN

TAP 1/4-28 UNF-2B 

.200[5.08] MIN

1

3.)    FOR BEST RESULTS, PLACE A THIN LAYER OF SILICONE GREASE (DOW CORNING #4 OR EQUIVALENT) ON 
        INTERFACE PRIOR TO MOUNTING.

 
        MOUNTING SURFACE SHOULD BE FLAT TO WITHIN .001[0.03] TIR WITH A MINIMUM  63 [1.6 ] FINISH FOR BEST RESULTS.
 
        DRILL PERPENDICULAR TO MOUNTING SURFACE TO WITHIN ±1°

1

2

1

Summary of Contents for IMI SENSORS D643A01

Page 1: ...y Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...642 643 647 648 A Series Industrial 4 20mA Sensor Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 8...

Page 5: ...ents Introduction Page 3 General Features Dimension Drawing Page 4 Operation and Wiring Page 5 Standard Wiring Taking Measurements RV Option TO Option Installation Page 9 ESD Sensitivity Page 10 Warra...

Page 6: ...er to specific specification sheets for further details General Features Imbedded Piezoelectric Accelerometer for improved accuracy and frequency response Vibration range can be in Acceleration or Vel...

Page 7: ...Dimension Drawing 1 05 26 7 PIN B NEGATIVE 4 20 mA PIN A POSITIVE 4 20 mA 1 8 HEX ALLEN KEY REQUIRED MOUNTING STUD MODEL 080A162 SUPPLIED 1 4 28 UNF 2A 3 4 16 UNF 2A 1 41 35 8 7 8 22 HEX 1 98 45 7 1 2...

Page 8: ...gative input from the power supply to Pin B or Blue wire of the sensor Figure 1 wiring loop powered Figure 2 wiring loop powered DC source If using a standard DC power supply install either an ammeter...

Page 9: ...25 ips pk 0 25 ips pk 0 5 ips pk 12 0 0 25 ips pk 0 5 ips pk 1 0 ips pk 15 75 0 37 ips pk 0 73 ips pk 1 47 ips pk 20 0 5 ips pk 1 0 ips pk 2 0 ips pk Measured mA 643AX0 643AX1 643AX2 4 00 0 0 ips rms...

Page 10: ...n signal for further analysis Figure 3 RV wiring For integral cable sensors RED 4 20mA Positive BLACK 4 20mA Negative same as green GREEN RV Acceleration Negative same as black WHITE RV Acceleration P...

Page 11: ...mperature sensor monitors the environment internal to the sensor housing and is situated at approximately mid level Figure 4 TO wiring For integral cable sensors RED 4 20mA Vibration Positive BLACK 4...

Page 12: ...PAGE 9 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Installation Installation should be performed per the following detail drawing for best performance...

Page 13: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Page 14: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Page 15: ...ed IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforeseen problems o...

Page 16: ...ExnA IIC T4 Hazardous Area Approval EEx ia IIC T4 40 C Ta 80 C II 1 G EEx ia IIC T4 40 C Ta 80 C II 1 G Hazardous Area Approval EEx nL IIC T4 40 C Ta 80 C II 3 G EEx nL IIC T4 40 C Ta 80 C II 3 G Haza...

Page 17: ...ALL MOUNTING SURFACES SEE ARROWS FIG 1 2 FIG 2 TIGHTEN THE MOUNTING STUD USING THE ALLEN KEY TORQUE THE MOUNTING STUD TO WITHIN 3 TO 4 FT LBS 4 1 TO 5 4 Nm FIG 3 THREAD THE SENSOR S HEX NUT ONTO THE...