Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

[email protected]

 

Repair inquiries

[email protected]

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for IMI SENSORS 685B0000A10

Page 1: ...n Switch Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ORING 685B Series Electronic Vibration Switch Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 9...

Page 7: ...ectromechanical Relays Pin Location Diagram Models with External Accelerometer and Triac Relays Pin Location Diagram Models with External Accelerometer and Electromechanical Relays Configuring the 685...

Page 8: ...accuracy and frequency response Vibration range can be measured in acceleration velocity or displacement factory set Provides dual 5 Amp Triac SPST or 10 Amp Form C SPDT relay outputs Adjustable trip...

Page 9: ...T or 10A 245Vac 5A 30Vdc Form C Relay SPDT Operating Temperature Range 22 to 158 F 30 to 70 C Storage Temperature Range 40 to 257 F 40 to 125 C Relative Humidity NEMA 4X Rating Case Dimension W x H x...

Page 10: ...o options to retrofit existing 3 bolt pattern installations Model 080A209 mounting plate required see optional accessories on page 13 Use grease between all surfaces to insure specified frequency resp...

Page 11: ...PAGE 6 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Standard Model Dimension Drawing with NPT Conduit Hubs Inch mm...

Page 12: ...ORING Explosion Proof Model Dimension Drawing Inch mm WARNING AC and DC input signals and power supply voltages could be hazardous DO NOT connect live wires to screw terminal plugs and DO NOT insert r...

Page 13: ...ug lightly on the wire to confirm connection is secure Pin Location Diagram Models with Internal Accelerometer and Triac Relays Pin Category Description 1 AC Power Power 2 Power Common 3 Earth Ground...

Page 14: ...ally Closed when dipswitch is in de energized position 5 Common connection 6 Normally Open when dipswitch is in de energized position 7 Alert Output Normally Closed when dipswitch is in de energized p...

Page 15: ...ate inside the top cover The cable shield to the accelerometer should be grounded as required by local codes as well as to limit RFI EMI interference Pin Category Description 1 AC Power Power 2 Power...

Page 16: ...red by local codes as well as to limit RFI EMI interference Pin Category Description 1 AC Power Power 2 Power Common 3 Earth Ground Also connect to enclosure safety lug 4 Alarm Output Normally Closed...

Page 17: ...age of the alarm value is reached Time delays for both functions are controlled using the second and fourth potentiometers Alert and alarm relays can be reset remotely by using the RESET and COMM pins...

Page 18: ...d alarm relays can be reset remotely by using the RESET and COMM pins or by using the internal reset switch as seen on the upper right hand corner of the diagram Using the first dipswitch beneath the...

Page 19: ...imulator repeat step 5 for the Alert signal 8 Adjust the SP Alert set point potentiometer to the point where the yellow Alert LED illuminates It is important to set the Alarm potentiometer first becau...

Page 20: ...PAGE 15 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Optional Accessories Model 080A209 Adapter Plate To retrofit old style vibration switch bolt patterns...

Page 21: ...INE CONDITION MONITORING Model 699A05 Portable 4 20 mA Calibrator Provides current output for 685B Series testing read out and calibration purposes Also receives and displays current signal from 4 20...

Page 22: ...ischarge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on and moving across a ru...

Page 23: ...Type two provided 0 Triac 5A 245vac 1 Form C Relay SPDT 10A 245Vac 5A 30Vdc Enclosure Type Hazardous Area Approval A1 Basic enclosure internal pushbutton for remote reset A2 Same as A1 plus external p...

Page 24: ......

Page 25: ......

Reviews: