background image

 

PAGE 9 

 

SENSO

RS AN

D INS

TRUME

N

TATIO

N F

OR MAC

HINE 

CON

DITION M

ONIT

ORIN

G

 

To Maintain Conformance, Earth Ground, Power Supply Common, and I/O Shields must 

be connected together. 

Note:  If using the 682 Power Supply, mount the 682 Signal Conditioner to the left of the power supply with a 
recommended minimum separation distance of 4” where applicable. 

Configuring the 682 Series 

Internal PC Board Diagram 
 

The Internal PC Board Diagram shows 
the location of the internal DIP Switch,  
Filter Modules, and Sensor Power 
Select Jumper. The DIP switch is used 
to configure the signal conditioner for 
various sensor and vibration ranges. 
The Filter Modules are installed to set 
the High and Low cutoff frequencies. 
The Jumper selects unregulated, 
regulated, or no ICP

®

 power to the 

accelerometer. 

The PC Board is accessible through 
the front of the indicator by removing 
the Screw Terminal Connectors and 
disengaging the tabs on the TOP and 
BOTTOM of the meter with a 
screwdriver. Once disengaged, the PC 
Board can be slid out for configuration. 

 

 

 

 

 

 

DIP Switch and Filter Module Descriptions:

 

S1 and S2:

 

Acceleration Mode 

S3 and S4:

 

Velocity Mode 

S5 and S6:

 

Displacement Mode 

S7:

 

 

RMS 

S8:

 

 

Peak 

S9: 

 

20g, 2ips, 40mils

 

Summary of Contents for IMI SENSORS 682B13

Page 1: ...mitter Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 716 684 3823 E mail i...

Page 2: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 3: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...Series 4 20mA Din Rail ICP Signal Conditioner Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800...

Page 7: ...f Contents Introduction Page 3 Block diagram Page 3 General Features Page 4 Installation and Wiring Page 5 Configuring the 682BX3 Page 9 ESD Sensitivity Page 12 Ordering Information Page 13 Warranty S...

Page 8: ...Displacement can be converted to a 4 20mA signal by simple DIP Switch selection internal to the Din Rail enclosure An additional standard feature of the 682 Series is the ability to convert the tempe...

Page 9: ...ion ranges include Acceleration g s Velocity in sec Displacement mils p p 5 00 0 50 10 0 10 00 1 00 20 0 20 00 2 00 40 0 Internal DIP switch selection for Peak or RMS Utilization of Filter Modules for...

Page 10: ...luids or machine oils IMI Sensors recommends mounting the 682BX3 in a type NEMA 4 enclosure to protect the electronics from contamination Dimension Drawing The Power LED is Green which turns on when t...

Page 11: ...closure in either the up or down direction terminate the wire in the correct location Do not exceed a torque of 0 5Nm Re install the terminal block This easy to assemble connection method allows devic...

Page 12: ...Pin 9 RV Pin 10 RV 4 to 20mA Temperature Output Pins 11 to 12 Pin 11 4 to 20mA Temperature Output Pin 12 4 to 20mA Temperature Output 4 to 20mA Vibration Output Pins 13 to 14 Pin 13 4 to 20mA Vibrati...

Page 13: ...PAGE 8 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Wiring Diagram 682 Series Signal Conditioner Signal Conditioner Power Supply 682A01 Power Supply...

Page 14: ...d Sensor Power Select Jumper The DIP switch is used to configure the signal conditioner for various sensor and vibration ranges The Filter Modules are installed to set the High and Low cutoff frequenc...

Page 15: ...OFF 1 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON OFF ON OFF 2 0 in sec RMS OFF OFF ON ON OFF OFF ON OFF ON OFF OFF 2 0 in sec Peak OFF OFF ON ON OFF OFF OFF ON ON OFF OFF 10 mils p p OFF OFF OFF OFF O...

Page 16: ...NSTRUMENTATION FOR MACHINE CONDITION MONITORING Sensor Power Jumper Configuration Factory Default Note If there is no DC bias on the input signal this will trigger the Open short detection which subtr...

Page 17: ...nt may be impaired if the equipment is used in a manner not specified by PCB Piezotronics Inc Caution 1 ESD sensitivity Cables can kill your equipment High voltage electrostatic discharge ESD can dama...

Page 18: ...the level of protection may be exceeded by extremely high voltage Ordering Information IMI Part Number 682A X 3 Frequency Response Isolation 0 3Hz to 10kHz Standard 1 3Hz to 1kHz 2 10Hz to 10kHz 3 10...

Page 19: ...ior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected with simple on site proce...

Page 20: ...price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days a week When unforese...

Page 21: ......

Page 22: ...LLETS AND RADII 0 07 0 13 OUTLINE DRAWING 40537 1 OF 1 FULL 4 20 DIN RAIL CONDITIONER DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JDM 5 31 16 ECB 5 31 16 CPH 5 31 16 40537 PCB Piezotronics Inc claim...

Reviews: