background image

  

INDUSTRIAL MONITORING INSTRUMENTATION DIVISION

 

PAGE 7 

 

SENSO

RS AN

D INS

TRUME

N

TATIO

N F

OR MAC

HINE 

CO

N

DITION M

ONIT

ORIN

G

 

 

W

arning 1 

– ESD Sensitivity 

 

 

The power supply/signal conditioner should not be opened by anyone other than qualified service 

personnel.  

This product is intended for use by qualified personnel who recognize shock hazards and are familiar 

with the safety precautions required to avoid injury. 

 

Warning 2 

– ESD Sensitivity 

 

This equipment is designed with user safety in mind. However, the protection provided by the equipment may be 

impaired if the equipment is used in a manner not specified by PCB Piezotronics, Inc. 

 

Caution 1 

– ESD Sensitivity 

 

Cables can kill your equipment.  

High voltage electrostatic discharge (ESD) can damage electrical devices.  

Similar to a capacitor, a cable can hold a charge caused by triboelectric transfer, such as that which occurs in the 

following: 

 

 

Laying on and moving across a rug,  

 

Any movement through air,  

 

The action of rolling out a cable, and/or 

 

Contact with a non-grounded person.  

 

The PCB solution for product safety: 

 

Connect the cables only with the AC power off. 

 

Temporarily “short” the end of the cable before attaching it to any signal input or output.  

 

Caution 2 

– ESD Sensitivity 

 

ESD considerations should be made prior to performing any internal adjustments on the equipment.  

Any 

piece of electronic equipment is vulnerable to ESD when opened for adjustments.  Internal adjustments should 

therefore be done ONLY at an ESD-safe work area.  Many products have ESD protection, but the level of 

protection may be exceeded by extremely high voltage. 

 

Summary of Contents for IMI DIVISION 699B02

Page 1: ...ty regimen When in doubt about a calibration cycle a good rule of thumb is to recalibrate on an annual basis It is also good practice to recalibrate after exposure to any severe temperature extreme sh...

Page 2: ...rchase Order should include authorization to proceed and return at current pricing which can be obtained from a factory customer service representative Contact Information International customers shou...

Page 3: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 4: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 5: ...N FOR MACHINE CONDITION MONITORING Model 699B02 Handheld Vibration Shaker Operating Guide with Enclosed Warranty Information 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684...

Page 6: ...NSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Table of Contents Introduction page 3 Description page 3 Maintenance Repair page 6 ESD Warning Information page 7 Warranty Servicing Warranty...

Page 7: ...ker Description Model 699B02 permits accurate adjustment of measuring instrumentation to indicate a standard acceleration level of 1 g RMS or 1 g peak adjusting the system for correct measurement The...

Page 8: ...indicating instrument may now be adjusted to read the relevant reference value Following the system adjustment the shaker is switched off by pressing the On Off button a second time To prolong the us...

Page 9: ...lly disconnected Figure 3 Peak vs RMS Selection with 100 mV g Accelerometer Calibration Check Points Calibration of the internal feedback circuit can be verified via test points located in the options...

Page 10: ...If factory service is required return the instrument to IMI A free quotation will be provided prior to servicing IMI a division of PCB Piezotronics Inc is an ISO 9001 certified company that has embra...

Page 11: ...voltage electrostatic discharge ESD can damage electrical devices Similar to a capacitor a cable can hold a charge caused by triboelectric transfer such as that which occurs in the following Laying on...

Page 12: ...ion will be provided prior to servicing at no charge Before returning the unit please consult a factory IMI applications engineer concerning the situation as certain problems can often be corrected wi...

Page 13: ...o have your purchase price refunded IMI offers to all customers at no charge 24 hour phone support This service makes product or application support available to our customers day or night seven days...

Page 14: ...d In the interest of constant product improvement we reserve the right tochange specifications without notice ICP is a registeredtrademarkof PCB Piezotronics Inc OPTIONAL VERSIONS Optional versions ha...

Page 15: ...II 003 005 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 8792 1 OF 1 625X MODEL 699A02 699B02 HAND HELD CALIBRATOR DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 KRM 11 1 18 KRM 11 1 18 CPH 11 1 18 8792...

Reviews: