Manual 21354 Rev E 
ECN 50523 

 

 

Component Name 

Hazardous Substances 

Lead (Pb)  Mercury (Hg) 

Cadmium (Cd) 

Chromium VI 
Compounds 
(Cr(VI)) 

Polybrominated 
Biphenyls (PBB) 

Polybrominated 
Diphenyl Ethers 
(PBDE) 

Housing 

PCB Board 

Electrical Connectors 

Piezoelectric Crystals 

Epoxy 

Teflon 

Electronics 

Thick Film Substrate 

Wires 

Cables 

Plastic 

Solder 

Copper Alloy/Brass 

This table is prepared in accordance with the provisions of SJ/T 11364. 
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit 
requirement of GB/T 26572. 

X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit 
requirement of GB/T 26572. 
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. 

Summary of Contents for ICP W138A02

Page 1: ...Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail i...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ducted over a single conductor coaxial cable with a shield serving as signal return Special low noise cables are not required Series 138 is used by the military for underwater explosive testing commer...

Page 7: ...high shock can flex the cable connector joint enough to move the center pin of the 10 32 cable connector This can cause noise on the output signal Protecting the connection from shock may be required...

Page 8: ...itioner If indicator is in green section of indicator panel the IC amplifier is producing proper bias 8 to 14 VDC cable connections are normal and the system is ready to operate If the needle moves to...

Page 9: ...sor l Keep connections clean and dry 2 Do not exceed specified maximum range 3 Do not subject sensor to temperaturesexceeding 100 F 4 Do not apply voltage to sensor withoutcurrent limiting diodes or o...

Page 10: ...nt Tourmaline Tourmaline HousingMaterial Stainless Steel Stainless Steel Electrical Connector 10 32 Coaxial Jack 10 32 Coaxial Jack Weight 0 61 oz 17 0 gm 4 All specifications are at room temperature...

Page 11: ......