PCB Piezotronics ICP W138A02 Installation And Operating Manual Download Page 3

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

CAUTION 

Refers to hazards that could damage 
the instrument.  

 

 

 

NOTE  

Indicates tips, recommendations and 
important information. The notes 
simplify processes and contain 
additional information on particular 
operating steps.  

 

The following symbols may be found on the equipment 
described in this manual: 

 

 

This symbol on the unit indicates that 
high voltage may be present.  Use 
standard safety precautions to avoid 
personal contact with this voltage.

 

 

 

This symbol on the unit indicates that 
the user should refer to the operating 
instructions located in the manual. 

 

 

This symbol indicates safety, earth 
ground.

 

 

 
 
 
 
 
 
 
 

 
 
 

 

 

Summary of Contents for ICP W138A02

Page 1: ...Sensor Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail i...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ducted over a single conductor coaxial cable with a shield serving as signal return Special low noise cables are not required Series 138 is used by the military for underwater explosive testing commer...

Page 7: ...high shock can flex the cable connector joint enough to move the center pin of the 10 32 cable connector This can cause noise on the output signal Protecting the connection from shock may be required...

Page 8: ...itioner If indicator is in green section of indicator panel the IC amplifier is producing proper bias 8 to 14 VDC cable connections are normal and the system is ready to operate If the needle moves to...

Page 9: ...sor l Keep connections clean and dry 2 Do not exceed specified maximum range 3 Do not subject sensor to temperaturesexceeding 100 F 4 Do not apply voltage to sensor withoutcurrent limiting diodes or o...

Page 10: ...nt Tourmaline Tourmaline HousingMaterial Stainless Steel Stainless Steel Electrical Connector 10 32 Coaxial Jack 10 32 Coaxial Jack Weight 0 61 oz 17 0 gm 4 All specifications are at room temperature...

Page 11: ......

Reviews: