background image

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

Component Name 

Hazardous Substances 

Lead (Pb)  Mercury (Hg) 

Cadmium (Cd) 

Chromium VI 
Compounds 
(Cr(VI)) 

Polybrominated 
Biphenyls (PBB) 

Polybrominated 
Diphenyl Ethers 
(PBDE) 

Housing 

PCB Board 

Electrical Connectors 

Piezoelectric Crystals 

Epoxy 

Teflon 

Electronics 

Thick Film Substrate 

Wires 

Cables 

Plastic 

Solder 

Copper Alloy/Brass 

This table is prepared in accordance with the provisions of SJ/T 11364. 
O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit 
requirement of GB/T 26572. 

X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above the limit 
requirement of GB/T 26572. 
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. 

Summary of Contents for ICP 221B05

Page 1: ...omp 1000 lb tension 1 mV lb Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...tallation outline drawing and specification sheet at the back of this manual for details and dimensions of the particular sensor model number s purchased The following pages give a brief description o...

Page 7: ...ring mounting and preload requirements Figure 4 outlines some possible mounting configurations to which the ring series may be installed Figure 4 Series 201 to 207 ICP Ring Force Sensor Possible Inst...

Page 8: ...simultaneously measuring force in three 3 orthogonal directions X Y and Z Internally three sets of quartz crystals are cut oriented and preloaded so the maximum output from the crystal cut for the spe...

Page 9: ...eturning the sensor to PCB for recalibration Figure 8 SERIES 3 COMPONENT TRIAX FORCE SENSORS PENETRATION Penetration style sensors are similar to the axial models but are specifically designed for com...

Page 10: ...t facing or surface grinding Surface flatness should be held to within 0 001 TIR over the entire mating surface When mounting sensors between two plates care should be taken to assure mounting surface...

Page 11: ...he left in Figure 13 part of the force between the two structures is shunted through the mounting stud The amount of force shunted is dependent on the stud material but may be up to 5 of the total for...

Page 12: ...itor the output from the Z axis connector when preloading 3 component type sensors These sensors require a preload in the Z axis that is 10 times their shear range Some models require this to be accom...

Page 13: ...hundreds of feet meters depending on the frequency of interest It is necessary to supply the sensor with a 2 to 20 mA constant current at 20 to 30 VDC through a current regulating diode or equivalent...

Page 14: ...ant in the system For this reason the readout device as well as the signal conditioner must be DC coupled Figure 16 Characteristic Discharge Time Constant Curve The discharge time constant represents...

Page 15: ...urned to the factory for servicing in the event of serious malfunction Observe the following precautions in using the sensor A Do not exceed the maximum load levels for the force sensor see specificat...

Page 16: ...2 Coaxial Jack 10 32 Coaxial Jack Electrical Connection Position Side Side Mounting Thread 1 4 28 Female 1 4 28 Female All specifications are at room temperature unless otherwise specified In the inte...

Page 17: ......

Reviews: