EX611 SERIES
INTERCONNECTIONS
1 OF 1
NONE
XXXX
.0005
JDM
5/3/16
ECB
5/3/16
GGS
5/3/16
NON-HAZARDOUS / SAFE AREA
HAZARDOUS AREA
DIV 1
ZONE 0
-
+
SENSOR
AMPLIFIER
VIN
≤
30V
SHIELD
NO CHANGES WITHOUT CSA APPROVAL
BARRIER
CABLE
TRANSDUCER
64
27
0
PCB Piezotronics Inc. claims proprietary rights in
the information disclosed hereon. Neither it nor any
reproduction thereof will be disclosed to others
without the written consent of PCB Piezotronics Inc.
REVISIONS
REV
DESCRIPTION
DIN
NR
RELEASED TO DRAFTING
45417
4
2
1
3
SCHEDULE DRAWING
NO MODIFICATIONS PERMITTED
WITHOUT REFERENCE TO THE
NOTIFIED BODY
CAUTION
ELECTROSTATIC
DISCHARGE SENSITIVE
Ci AND Li BASED ON CABLE WITH 30 pF/ft AND .33
μ
H/ft WITH A MAXIMUM CABLE
LENGTH OF 100ft. Ci AND Li WILL BE DECREASED WITH SHORTER CABLE LENGTHS.
SHIELDS TO BE EARTHED AT BARRIER END.
THE INSTALLER SHALL INSURE THAT THE TRANSDUCER MOUNTING
STRUCTURE IS AT THE SAME GROUNDING POTENTIAL AS THE BARRIER
GROUND. TOTAL EARTH LOOP IMPEDANCE SHALL BE LESS THAN
ONE OHM.
BARRIER WILL BE MOUNTED IN AN ENCLOSURE THE SUITABILITY
OF WHICH WILL BE DETERMINED BY LOCAL AUTHORITIES.
ENTITY APPLICATION:
Barrier I.S. Apparatus
Voc/Uo < V /Ui
Isc/Io I /Ii
Ca/Co Ci + C
La/Lo Li + L
Po < Pi (CENELEC ONLY)
BARRIERS WITHIN THE SPECIFIED LIMITATIONS ARE PERMITTED.
ENTITY PARAMETERS:
Ui = 30 V
Ii 100 mA
Pi 0.7 W
Ci 3300 pF
Li 30
μ
H
CERTIFIED BY THE APPROPRIATE APPROVAL AUTHORITY FOR CONNECTION
TO THE FOLLOWING AREAS:
ZONE 0
Exia IIC
AExia IIC
DIV 1
CLASS I, GROUPS A,B,C,D
CLASS II, GROUPS E,F,G
CLASS III