Repair and Maintenance 

 

 

PCB guarantees Total Customer Satisfaction through its 

“Lifetime  Warranty  Plus”  on all  Platinum  Stock  Products 

sold by PCB and through its limited warranties on all other 
PCB  Stock,  Standard  and  Special  products.  Due  to  the 
sophisticated  nature  of  our  sensors  and  associated 
instrumentation, 

field  servicing  and  repair  is  not 

recommended  and,  if  attempted,  will  void  the  factory 
warranty

 
Beyond  routine  calibration  and  battery  replacements 
where  applicable,  our  products  require  no  user 
maintenance.  Clean  electrical  connectors,  housings,  and 
mounting surfaces with solutions and techniques that will 
not  harm  the  material  of  construction.  Observe  caution 
when using liquids near devices that are not hermetically 
sealed.  Such  devices  should  only  be  wiped  with  a 
dampened cloth

never saturated or submerged.  

 

In the event that equipment becomes damaged or ceases 
to operate, our Application Engineers are here to support 
your  troubleshooting  efforts  24  hours  a  day,  7  days  a 
week. Call or email with model and serial number as well 
as a brief description of the problem. 

 

Calibration 

 

 

Routine 

calibration 

of 

sensors 

and 

associated 

instrumentation  is  necessary  to  maintain  measurement 
accuracy. We recommend calibrating on an annual basis, 
after  exposure  to  any  extreme  environmental  influence, 
or prior to any critical test.  

 

PCB Piezotronics is an ISO-9001 certified company whose 
calibration  services  are  accredited  by  A2LA  to  ISO/IEC 
17025,  with  full  traceability  to  SI  through  N.I.S.T.  In 
addition to our standard calibration services, we also offer 
specialized  tests,  including:  sensitivity  at  elevated  or 
cryogenic  temperatures,  phase  response,  extended  high 
or low frequency response, extended range, leak testing, 
hydrostatic  pressure  testing,  and  others.  For  more 
information,  contact  your  local  PCB  Piezotronics 
distributor,  sales  representative,  or  factory  customer 
service representative.  

 

Returning Equipment 

 

If  factory  repair  is  required,  our  representatives  will 
provide you with a Return Material Authorization (RMA) 
number, which we use to reference any information you 
have  already  provided  and  expedite  the  repair  process. 
This number should be clearly marked on the outside of 
all  returned  package(s)  and  on  any  packing  list(s) 
accompanying the shipment.  

 

Contact Information 

 

 

PCB Piezotronics, Inc.  
3425 Walden Ave. 
Depew, NY14043 USA  
Toll-free: (800) 828-8840 
24-hour SensorLine: (716) 684-0001 
General inquiries

[email protected]

 

Repair inquiries

[email protected]

  

 

For a complete list of distributors, global offices and sales 
representatives, visit our website, 

www.pcb.com

 

 

Safety Considerations

 

 

This  product  is  intended  for  use  by  qualified  personnel 
who  recognize  shock  hazards  and  are  familiar  with  the 
precautions required to avoid injury. While our equipment 
is  designed  with  user  safety  in  mind,  the  protection 
provided by the equipment may be impaired if equipment 
is used in a manner not specified by this manual.  

 

Discontinue use and contact our 24-Hour Sensorline if: 

 

 

Assistance is needed to safely operate equipment 

 

Damage is visible or suspected 

 

Equipment fails or malfunctions 

 

For  complete  equipment  ratings,  refer  to  the  enclosed 
specification sheet for your product. 

 

Definition of Terms and Symbols 

 

 

The following symbols may be used in this manual: 

 

 

DANGER 

Indicates an immediate hazardous 
situation, which, if not avoided, may 
result in death or serious injury.

 

 

Summary of Contents for EX378B02

Page 1: ...ystem Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mai...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...in which the instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument St...

Page 7: ...owered with a 24V or a 12V phantom power supply but this will limit the maximum output voltage Externally Polarized Microphone System Prepolarized Microphone System Phantom Powered Microphone System T...

Page 8: ...em such as the preamplifier signal conditioner or instrumentation Conversely the Cartridge Thermal Noise CTN specification provides the lowest measurable sound pressure level that can be detected abov...

Page 9: ...rugged grid cap shown below and as an independent part of a rugged kit to extend the lifespan of the precision measuring device caution should be taken to ensure the delicate diaphragm sensing element...

Page 10: ...ustry standards ensures accurate calibra tion against relevant specifications We also carry a line of acoustic calibrators that can be used to calibrate microphone sensitivity on site as needed Hand c...

Page 11: ...ow 1 to 2 minutes for the system to stabilize The meter or LED on the signal conditioner should be reading green This indicates proper operation and you may begin taking measurements If a faulty condi...

Page 12: ...outine calibration of sensors by the manufacturer is recommended as this helps build confidence in measurement accuracy and acquired data Danger Areas for pressure relief devices N A not a pressure re...

Page 13: ...14043 3425 Walden Ave Depew New York 14043 No 65238 No 3 of 3 Rev NR ECO 45769 Note Literature such as the manual or marketing materials describing the equipment or protective system must not contrad...

Page 14: ...d a voltage be supplied to an ICP Microphone System without a current regulating diode or equivalent electrical circuit This may include ohmmeters multi meters and continuity testers Safe Use After co...

Page 15: ...highly recommended to keep spare cables on hand to enable continuation of the test in the event of a cable failure Install Microphone system per drawing 68216 Adjustment The EX378XYYY series come ass...

Page 16: ...IV 1 GROUPS A B C D CODE IDENT NO 52681 DWG NO SCALE SHEET DRAWN CHECKED ENGINEER TITLE UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DECIMALS X 05 XX 01 XXX 005 ANGLES 2 DEGREES FILLETS AND RAD...

Page 17: ...oltage 7 Vpk 7 Vpk Output Impedance 50 Ohm 50 Ohm Physical Housing Material Stainless Alloy Stainless Alloy Venting Rear Rear 4 Electrical Connector BNC Jack BNC Jack Mounting Thread Grid 0 5 60 UNS 0...

Page 18: ...MICROPHONE DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 KRM 3 1 18 KRM 3 1 18 GGS 3 1 18 66401 PCB Piezotronics Inc claims proprietary rights in the information disclosed hereon Neither it nor any r...

Page 19: ...ia IIC T4 Ga I M1 Ex ia I CODE IDENT NO 52681 DWG NO SCALE SHEET DRAWN CHECKED ENGINEER TITLE UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN INCHES DECIMALS X 05 XX 01 XXX 005 ANGLES 2 DEGREES FILLETS...

Page 20: ...stem Type Ex378XYYY Optional accessory Type of Protection Ex ia Marking Ex ia I Ma Ex ia IIC T4 Ga Approved for issue on behalf of the lECEx Certification Body Position Signature for printed version D...

Page 21: ...ns as set out in lECEx Scheme Rules lECEx 02 and Operational Documents as amended STANDARDS The electrical apparatus and any acceptable variations to it specified in the schedule of this certificate a...

Page 22: ...e the interface to an external cable assembly The equipment is intended to be used for leak detection and acoustic noise tests in gaseous or mining explosive areas SPECIFIC CONDITIONS OF USE YES as sh...

Page 23: ...trinsic safety 1 EN 61326 1 2013 Electrical Equipment for Measurement Control and Laboratory Use EMC EN 61326 2 3 2013 Electrical Equipment for Measurement Control and Laboratory Use EMC EN 61010 1 20...

Page 24: ...venue du G n ral Leclerc FR 92260 Fontenay aux Roses Tel 33 1 40 95 60 60 Fax 33 1 40 95 86 56 I the undersigned hereby declare that the equipment specified above conforms to the a W Direce Standard s...

Page 25: ...nfidentiel s No report s N 144457 692709 8 Le respect des Exigences Essentielles de S curit et de Compliance with the Essential Health and Safety Sante est assure par la conformit a Requirements has b...

Page 26: ...nd a preamplifier The delivered signal from lOP Microphone Systems provides a typical 1 7V peak voltage output signal when making acoustic measurements The microphone cartridge is the sensing element...

Page 27: ...r metallic body and cable shield are reliably connected to the system earth The apparatus must be connected according to instruction manual For final installation the user shall take all necessary pre...

Reviews: