background image

 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Summary of Contents for 482B06

Page 1: ...oner for ICP Sensors Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Page 2: ... repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment calibration cycles are typically established by the users own quality regimen When in doubt about a calibration cycle a good rule...

Page 3: ...ory customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and mounting hardware are not covered by warranty Mechanical damage...

Page 4: ... O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ...te O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at le...

Page 6: ...duction 1 2 0 Description 1 3 0 Installation 2 4 0 Coupling Time Constant AC Coupled 2 4 1 Driving Long Cables 3 4 2 Setting the Constant Current 3 5 0 Warranty 3 6 0 Maintenance and Repair 4 Appendix Specification Sheet Outline Drawing Table of Figures Figure 1 482B06 Front Panel 2 Figure 2 Fault Monitor Table 2 Figure 3 Constant Current Adjust 3 ...

Page 7: ...ld therefore be done ONLY at an ESD safe work area Many products have ESD protection but the level of protection may be exceeded by extremely high voltage The Caution heading used in this manual explains hazards that could damage the instrument 1 2 Introduction The Model 482B06 F482B06 is a single channel line operated signal conditioner for use with ICP sensor This unit provides a 24VDC 4mA const...

Page 8: ...ect a typical bias of 8 to 12 volts It does not read midscale if the transducer bias is 3 to 5 volts and may be closer to red which is expected for low bias sensors If a cable is faulty open or the sensor s built in amplifier is open the meter indicates a yellow full scale reading When a cable or sensor is shorted the meter indicates zero volts red Connect the output jack to a read out instrument ...

Page 9: ... Another technique requires the use of the Model 073A Impedance Matching Resistor connected immediately after the sensor This variable resistor is then used to tune the current to the line One of the best approaches is to test the long line with a signal generator set at a frequency of interest 4 2 Setting the Constant Current To set the constant current locate the current adjust potentiometer on ...

Page 10: ...oncerning the difficulty and to ascertain if an on site procedure rectifies the problem If repair is indicated contact PCB to request a Return Materials Authorization RMA number from the factory An advanced authorization to proceed with the repair permitting charges of up to 50 of a new item greatly expedites repair For the most efficient service please provide a detailed written description of th...

Page 11: ... BNC Jack Connector Output BNC Jack BNC Jack Connector AC Power Input IEC 320 IEC 320 Size Height x Length x Width 4 3 in x 6 0 in x 1 8 in 10 92 cm x 15 24 cm x 4 57 cm Weight 1 2 lb 544 gm All specifications are at room temperature unless otherwise specified In the interest of constant product improvement we reserve the right to change specifications without notice ICP is a registered trademark ...

Page 12: ......

Reviews: