background image

 
 
 
 
 
 
 
 
 
 
 

DOCUMENT NUMBER: 21354 
DOCUMENT REVISION: 

C

 

ECN: 45605 

 

Component Name 

Hazardous Substances 

Lead 
(Pb) 

Mercury 
(Hg) 

Cadmium 
(Cd) 

Chromium VI 
Compounds 
(Cr(VI)) 

Polybrominated 
Biphenyls 
(PBB) 

Polybrominated 
Diphenyl 
Ethers (PBDE) 

Housing 

PCB Board 

Electrical 
Connectors 

Piezoelectric 
Crystals 

Epoxy 

Teflon 

Electronics 

Thick Film 
Substrate 

Wires 

Cables 

Plastic 

Solder 

Copper Alloy/Brass 

This table is prepared in accordance with the provisions of SJ/T 11364. 

O: Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit 
requirement of GB/T 26572. 

X: Indicates that said hazardous substance contained in at least one of the homogeneous materials for this part is above 
the limit requirement of GB/T 26572. 
Lead is present due to allowed exemption in Annex III or Annex IV of the European RoHS Directive 2011/65/EU. 

Summary of Contents for 482A23/NP

Page 1: ...ne or DC Powered Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 098...

Page 2: ...repair User servicing or repair is not recommended and if attempted may void the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps...

Page 3: ...ry customer service representative Warranty All equipment and repair services provided by PCB Piezotronics Inc are covered by a limited warranty against defective material and workmanship for a period...

Page 4: ...isclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O O X O O O O O...

Page 5: ...e O O X O O O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indica...

Page 6: ...grounded person The solution for product safety 1 Connect the cables only with the AC power off 2 Temporarily short the end of the cable before attaching it to any signal input or output Caution 2 ESD...

Page 7: ...ought out to the OUTPUT jack The bias monitor located on the front panel consists of a color coded panel meter that permanently monitors the sensor bias level See sensor specification for correct sens...

Page 8: ...tant current drive to the transducers 482A21 is normally supplied with the constant current output to the transducer set at 4 mA nominal This is adequate for most laboratory and field applications Spe...

Page 9: ...ative concerning the difficulty to ascertain if an on site procedure rectifies the problem If repair is indicated contact PCB to request a Return Materials Authorization RMA number from the factory An...

Page 10: ...select matches the channel of interest Output signal seems to drift Make sure the input impedance of the readout device scope or data acquisition system is approximately 1 M Low frequency response not...

Page 11: ......

Page 12: ...ght x Width x Length 6 3 in x 2 4 in x 11 in 16 cm x 6 1 cm x 28 cm Weight 1 51 lb 685 gm All specifications are at room temperature unless otherwise specified In the interest of constant product impr...

Page 13: ......

Reviews: