background image

 

 

 
 

PRODUCT GUIDE 

377 SERIES MICROPHONES 

426 SERIES PREAMPLIFIERS 

 

Contents: 

1.0

 

Introduction ................................................................................ 1

 

2.0

 

Standards .................................................................................... 1

 

3.0

 

Setting up a Microphone Measurement System ........................ 1

 

4.0

 

Taking Measurements ................................................................ 2

 

5.0

 

Accessories ................................................................................. 3

 

6.0

 

Maintenance ............................................................................... 3

 

7.0

 

Calibration .................................................................................. 4

 

8.0

 

Warranty and Service ................................................................. 4

 

 

1.0

 

Introduction 

Thank you for your purchase of a PCB high quality microphone. These microphones offer highly accurate 
and reliable acoustic measurements and are typically used in research and design applications. They are 
accurate enough for laboratory usage, yet rugged enough for field-testing. 

Sound within the typical 20 to 20,000 Hz audible range of a healthy human ear can either be pleasing to 
the ear, as in music, or unpleasant (or harmful), as in noise. As a result, many applications, from the de-
velopment of consumer products to research in acoustics, measure sound, even sound outside the range of 
human  hearing.  The  instrument  typically  used  to  measure  sound  is  the  microphone,  which  is  designed, 
like the human ear, to transform pressure oscillations into a corresponding voltage oscillation. 

2.0

 

Standards 

Before selecting an acoustical instrument, it is important to identify which acoustical standards are appro-
priate for the application in which the instrument will be used. Whether for legal purposes or for quality 
assurance programs, these standards will help determine the required quality, accuracy and consistency of 
the instrument.  Standards  that correspond to  the  performance requirements,  dimensions  and characteris-
tics  of  acoustical  components  are  established  for  microphones,  sound  level  meters,  calibrators,  or  other 
related  components.  The  most  common  organizations  producing  these  standards  are  the  American  Na-
tional  Standards  Institute  (ANSI)  and  the  International  Electrotechnical  Commission  (IEC).  IEC  1094-4 
establishes  specifications  for  the  mechanical  dimensions  and  certain  electroacoustic  characteristics  for 
standard  industrial  microphones.  The  performance  specification  sheet  supplied  with  each  PCB  micro-
phone identifies the standards to which the microphone is compliant. 

3.0

 

Setting up a Microphone Measurement System 

After the proper microphone has been selected, the corresponding preamplifier, cabling, power supplies, 
signal conditioning and data acquisition selections are ready to be installed. Not all of these components 
are required for all test set-ups. The figures below show typical set-ups for externally polarized and pre-
polarized microphone systems. 

A prepolarized microphone can be used with a standard Microphone Power Supply designed for external-
ly polarized microphones, and its preamplifier, provided the supply voltage is set to zero. 

Summary of Contents for 378B20

Page 1: ...e 377B20 426E01 installation and operating manuals that comprise a Model 378B20 ICP Microphone System kit For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 8...

Page 2: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 3: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 4: ...he instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument Standards th...

Page 5: ...ponse reactions of the human ear to the pressure fluctuations Some examples of typical sound pressure levels are shown in the table below dB Pressure Example 0 0 00002 Pa Threshold of Hearing 60 0 02...

Page 6: ...and noise cones the fre quency response of the microphone will be attenuated at higher frequencies Clamps and stands When holding a microphone in place it is important to minimize the influence of the...

Page 7: ...2LA manufacturers Our internal metrology laboratory is certified to ISO 9001 accredited by A2LA to AN SI IEC 17025 and ANSI NCSL Z540 1 complies with ISO 10012 1 and former MIL STD 45662A and uses equ...

Page 8: ...VDC Output Impedance 50 Ohm 50 Ohm Maximum Output Voltage 7 Vpk 7 Vpk Physical Housing Material Stainless Alloy Stainless Alloy Venting Rear Rear 6 Electrical Connector BNC Jack BNC Jack Mounting Thre...

Page 9: ......

Page 10: ...Microphone Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E m...

Page 11: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 12: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 13: ...he instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument Standards th...

Page 14: ...ponse reactions of the human ear to the pressure fluctuations Some examples of typical sound pressure levels are shown in the table below dB Pressure Example 0 0 00002 Pa Threshold of Hearing 60 0 02...

Page 15: ...and noise cones the fre quency response of the microphone will be attenuated at higher frequencies Clamps and stands When holding a microphone in place it is important to minimize the influence of the...

Page 16: ...2LA manufacturers Our internal metrology laboratory is certified to ISO 9001 accredited by A2LA to AN SI IEC 17025 and ANSI NCSL Z540 1 complies with ISO 10012 1 and former MIL STD 45662A and uses equ...

Page 17: ...20 Pa 1 Electrical Capacitance Polarized 11 pF 11 pF 1 Polarization Voltage 0 V 0 V 2 Physical Housing Material Stainless Alloy Stainless Alloy Venting Rear Rear Mounting Thread Preamplifier 0 4606 60...

Page 18: ...ARIZED MICROPHONES DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JDM 9 14 05 ECB 9 14 05 CCL 9 14 05 1 1 2 2 A A B B 60 15 3 64 16 4 36 9 2 50 12 7 4606 60 UNS 11 7 mm 60 UNS THREADS 52 13 2 47 12 0 4...

Page 19: ...plifier Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail...

Page 20: ...id the factory warranty Calibration Routine calibration of sensors and associated instrumentation is recommended as this helps build confidence in measurement accuracy and acquired data Equipment cali...

Page 21: ...warranty against defective material and workmanship for a period of one year from date of original purchase Contact PCB for a complete statement of our warranty Expendable items such as batteries and...

Page 22: ...he instrument will be used Whether for legal purposes or for quality assurance programs these standards will help determine the required quality accuracy and consistency of the instrument Standards th...

Page 23: ...ponse reactions of the human ear to the pressure fluctuations Some examples of typical sound pressure levels are shown in the table below dB Pressure Example 0 0 00002 Pa Threshold of Hearing 60 0 02...

Page 24: ...and noise cones the fre quency response of the microphone will be attenuated at higher frequencies Clamps and stands When holding a microphone in place it is important to minimize the influence of the...

Page 25: ...2LA manufacturers Our internal metrology laboratory is certified to ISO 9001 accredited by A2LA to AN SI IEC 17025 and ANSI NCSL Z540 1 complies with ISO 10012 1 and former MIL STD 45662A and uses equ...

Page 26: ......

Page 27: ......

Reviews: