Manual 21354 Rev E 
ECN 50523 

 

 

CAUTION 

Refers to hazards that could damage 
the instrument.  

 

 

 

NOTE  

Indicates tips, recommendations and 
important information. The notes 
simplify processes and contain 
additional information on particular 
operating steps.  

 

The following symbols may be found on the equipment 
described in this manual: 

 

 

This symbol on the unit indicates that 
high voltage may be present.  Use 
standard safety precautions to avoid 
personal contact with this voltage.

 

 

 

This symbol on the unit indicates that 
the user should refer to the operating 
instructions located in the manual. 

 

 

This symbol indicates safety, earth 
ground.

 

 

 
 
 
 
 
 
 
 

 
 
 

 

 

Summary of Contents for 3711E1110G

Page 1: ...elerometer Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E ma...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ures a proof mass ring frame and attachment system between the two These features are bulk micro machined from the same single crystal silicon wafer The movement of the proof mass is directly affected...

Page 7: ...mounting method while two part epoxies can be used for a more secure mount To remove an adhesively mounted sensor it is best to place an open ended wrench over the sensor and twist it to shear the adh...

Page 8: ...lculate the sensitivity of the accelerometer refer to equation 8 1 Sensitivity 1g 1g Eq 8 1 2 9 0 Sensor Calibration Due to ISO 9001 ISO Guide 25 or other contractual require ments it may become neces...

Page 9: ...5 in x 0 85 in 11 4 mm x 21 6 mm x 21 6 mm Weight 0 58 oz 16 3 gm Electrical Connector 4 Pin 4 Pin Electrical Connection Position Side Side Mounting Through Holes 2 Through Holes 2 All specifications...

Page 10: ...ARATION 089 2 26 220 5 59 MIN 4 40 UNC 2B 170 4 32 MIN METRIC MOUNTING HOLE PREPARATION 081 2 05 180 4 57 MIN M2 5 X 45 6H 130 3 30 MIN 5 SEE SHEET 2 OF 2 FOR CABLE STRAIN RELIEF INFORMATION RECOMMEND...

Page 11: ...OUT PULLING CABLE DETACHABLE 4 SOCKET PLUG TO 1 4 28 4 SOCKET PLUG TEST STRUCTURE FASTEN CABLE TO TEST STRUCTURE TYPICALLY WITHIN 2 3 51 76 OF SENSOR THEN FASTEN AGAIN WITHIN 3 4 76 101 OF PREVIOUS AT...