10.0   TROUBLESHOOTING   

 

When a PCB signal conditioner with any of the following 

indicators are used, turn the power on and observe the voltmeter 

(or LED’s) on the front panel.   

 

 

 

NORMAL OPERATION 

 

 

Output voltage moves from YELLOW to GREEN slowly until 

charging is complete.  AC coupled signal conditioners require 

sufficient time to charge the internal coupling capacitor.  Allow 

signal conditioner to charge for five (5)  discharge time 

constants for stable operation.  In most cases, this is just a few 

seconds. 

 

Note: Most PCB force sensors have an output bias of 8-14 

VDC.  Refer to the specification sheet in this manual for the 

bias range of the model you are using.  If you are using a low 

bias sensor, the indicator will be at the bottom end of the green 

portion of the dial indicator, and may even be in the red portion. 

This is the expected range and indicates proper operation. 

 

 

11.0   MAINTENANCE 

 

The sensor connector must be kept clean, especially if it is 

operating in a dusty and/or wet environment.  Because the force 

sensor is of welded construction, it should be returned to the 

factory for servicing in the event of serious malfunction. 

 

Observe the following precautions in using the sensor: 

 

A.

 

Do not exceed the maximum  load levels for the force 

sensor (see specification sheet).  

 

B.

 

Do not subject the sensor to temperatures exceeding that 

of the specification, normally 250°F (121°C). 

 

C.

 

Do not apply voltage to the sensor without current-

limiting diodes or other current protection. 

 

D.

 

Do not apply more than 20 mA of current to the force 

sensor. 

 

E.

 

When mounting the force sensor, observe installation 

procedures detailed in Section 3.0 and as outlined on the 

specific sensor Installation Drawing to avoid over-

torquing when mounting. 

 

F.

 

Do not apply more than 30 volts to the sensor. 

 

G.

 

Avoid metal-to-metal impacts

 during applications as this 

application produces high-frequency energy and ringing 

within the sensor which could damage the internal 

crystal(s) or ICP amplifier.  Electrical low-pass filtering 

or a mechanical damping material can help reduce such 

effects. 

 

H.

 

Do not spin the sensor onto the cable

.  This may fatigue 

the cable center pin, causing cable damage.  Always 

insert the cable pin into the sensor and tighten the 

knurled cable nut to the sensor.  

 

 

ICP

 is a registered trademark of PCB Piezotronics 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MANUAL NUMBER:  18218 

MANUAL REVISION

 J

 

ECN NUMBER: 

53133

 

Summary of Contents for 201B01

Page 1: ... lb comp 500 mV lb Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E mail info pcb com Web www pcb com ...

Page 2: ...ialized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For more information contact your local PCB Piezotronics distributor sales representative or factory customer service representative Returning Equipment If factory repair is required our representatives ...

Page 3: ...ation on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety precautions to avoid personal contact with this voltage This symbol on the unit indicates that the user should refer to the operating instructions located in the manual This symbol indicates safety ea...

Page 4: ...E 住房 O O O O O O PCB板 X O O O O O 电气连接器 O O O O O O 压电晶体 X O O O O O 环氧 O O O O O O 铁氟龙 O O O O O O 电子 O O O O O O 厚膜基板 O O X O O O 电线 O O O O O O 电缆 X O O O O O 塑料 O O O O O O 焊接 X O O O O O 铜合金 黄铜 X O O O O O 本表格依据 SJ T 11364 的规定编制 O 表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 X 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 铅是欧洲RoHS指令2011 65 EU附件三和附件四目前由于允许的豁免 CHINA RoHS COMPLIANCE ...

Page 5: ... O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that said hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement of GB T 26572 X Indicates that said hazardous substance contained in at least one of t...

Page 6: ...stallation outline drawing and specification sheet at the back of this manual for details and dimensions of the particular sensor model number s purchased The following pages give a brief description of the various sensor series available recommended mounting procedures operation and recommended calibration In addition to PCB s line of ICP sensors each ICP sensor series outlined has corresponding ...

Page 7: ...e ring mounting and preload requirements Figure 4 outlines some possible mounting configurations to which the ring series may be installed Figure 4 Series 201 to 207 ICP Ring Force Sensor Possible Installation Methods GENERAL PURPOSE RADIAL Model 208C01 C05 General Purpose Sensors are designed to measure compression and impact forces from a fraction of a lb N to 5 000 lbs to 22 24 kN Tension force...

Page 8: ... simultaneously measuring force in three 3 orthogonal directions X Y and Z Internally three sets of quartz crystals are cut oriented and preloaded so the maximum output from the crystal cut for the specific plane is obtained when a force is applied axially to the specific x y or z plane Sensor output from loads applied in the alternate transverse planes considered channel cross talk is negligible ...

Page 9: ...returning the sensor to PCB for recalibration Figure 8 SERIES 3 COMPONENT TRIAX FORCE SENSORS PENETRATION Penetration style sensors are similar to the axial models but are specifically designed for compression and impact force measurements in materials testing applications Smooth cylindrical housings and curved impact caps avoid cutting through specimens This enables measurements to be taken to de...

Page 10: ...ot facing or surface grinding Surface flatness should be held to within 0 001 TIR over the entire mating surface When mounting sensors between two plates care should be taken to assure mounting surfaces are flat and parallel Non parallel surfaces could place unwanted stress on internal components leading to premature sensor failure The protective cap should remain on the electrical connector durin...

Page 11: ...the left in Figure 13 part of the force between the two structures is shunted through the mounting stud The amount of force shunted is dependent on the stud material but may be up to 5 of the total force for the beryllium copper stud supplied with the sensor and up to 50 for steel studs This typical installation setup is used by PCB during standard calibrations of force ring models 201B01 through ...

Page 12: ...nitor the output from the Z axis connector when preloading 3 component type sensors These sensors require a preload in the Z axis that is 10 times their shear range Some models require this to be accomplished in steps not to exceed the usable voltage To prevent clipping of the signal increments should not exceed 10 VDC Figure 14 ICP Force Sensor Preload Requirements WORKING RANGE PRELOAD AND MAXIM...

Page 13: ... hundreds of feet meters depending on the frequency of interest It is necessary to supply the sensor with a 2 to 20 mA constant current at 20 to 30 VDC through a current regulating diode or equivalent circuit contained in all PCB signal conditioners See Guide G 0001B for powering and signal conditioning information pertaining to all ICP instrumentation Most of the line powered signal conditioners ...

Page 14: ...tant in the system For this reason the readout device as well as the signal conditioner must be DC coupled Figure 16 Characteristic Discharge Time Constant Curve The discharge time constant represents the decay rate of an input signal One DTC represents the amount of time taken for the signal to decay to 37 of the initial peak value As illustrated in Figure 16 this is an exponential decay Approxim...

Page 15: ...turned to the factory for servicing in the event of serious malfunction Observe the following precautions in using the sensor A Do not exceed the maximum load levels for the force sensor see specification sheet B Do not subject the sensor to temperatures exceeding that of the specification normally 250 F 121 C C Do not apply voltage to the sensor without current limiting diodes or other current pr...

Page 16: ... Connector 10 32 Coaxial Jack 10 32 Coaxial Jack Electrical Connection Position Side Side All specifications are at room temperature unless otherwise specified In the interest of constant product improvement we reserve the right to change specifications without notice ICP is a registered trademark of PCB Group Inc OPTIONAL VERSIONS Optional versions have identical specifications and accessories as...

Page 17: ......

Page 18: ......

Reviews: