background image

 

 

 

 
Manual 21354 Rev E 
ECN 50523 

 

 

 

 

 

 

 

 

PCB

业监视和测量设备

 - 

中国

RoHS2

公布表

 

PCB Industrial Monitoring and Measuring Equipment - China RoHS 2 Disclosure Table 

部件名称

 

有害物

 

 (Pb) 

 

(Hg) 

 

(Cd) 

六价

 (Cr(VI)) 

多溴

联苯

 (PBB) 

多溴二苯

 (PBDE) 

住房

 

PCB

 

电气连接

 

压电晶

 

 

铁氟龙

 

 

厚膜基板

 

电线

 

电缆

 

塑料

 

 

铜合金

/

 

本表格依据

 SJ/T 11364 

规定编制

 

O

 

表示

该有害物质在该部件所有均质材料中的含量均在

 GB/T 26572 

规定的限量要求以下

 

X

 

表示

该有害物质至少在该部件的某一均质材料中的含量超出

 GB/T 26572 

规定的限量要求。

 

铅是欧洲

RoHS

指令

2011/65/ EU

附件三和附件四目前由于允

许的豁免

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CHINA RoHS COMPLIANCE 

 

 

 

 

Summary of Contents for 130B40

Page 1: ...MICROPHONE Installation and Operating Manual For assistance with the operation of this product contact PCB Piezotronics Inc Toll free 800 828 8840 24 hour SensorLine 716 684 0001 Fax 716 684 0987 E m...

Page 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Page 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Page 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Page 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Page 6: ...ncerning the Microphone or its application feel free to call a factory Application Engineer at 716 684 0001 or your local dedicated PCB Sales Engineer 2 0 Product Description The PCB 130B series of Su...

Page 7: ...or adhesive or flush mounting Additionally the mesh of the microphone s protective grid repels water Figure 2 Typical pressure frequency response curve of Series 130B Series Surface Microphones 3 0 Po...

Page 8: ...lation and Operation 4 1 Mounting Methods Consider the expected air flow across the surface on which the Surface Microphone will be mounted to determine the best way to secure the microphone to the su...

Page 9: ...to its mounting surface Figure 5 One sided Adhesive Pad securing the Surface Microphone and Fairing in place Moderate to heavy air flow Microphone Top single sided adhesive pad Base double sided adhes...

Page 10: ...urface Figure 6 Double sided adhesive pad NOTE If the Surface Microphone will be mounted in a location where no air movement is expected the pad can be trimmed beforehand to fit the microphone if desi...

Page 11: ...The microphone is checked against a test and measurement working standard microphone and must meet specifications before it can be shipped An example of the result of one of the tests is shown above...

Page 12: ...nt Press down slightly to ensure a seal and to minimize outside noise then perform the calibration using the instructions provided in the calibrator s manual 6 0 Service See the supplemental sheet con...

Page 13: ...t 1 5 m Cable Termination 10 32 Coaxial Plug 10 32 Coaxial Plug Size Diameter Without fairing 0 52 in 13 2 mm Size Diameter With fairing 1 62 in 41 0 mm Size Height 0 126 in 3 20 mm Weight 0 3 oz 7 gm...

Page 14: ......

Reviews: